Clinical and in vitro evaluation of mandibular angle fracture fixation with the two-miniplate system
Autor: | Ho Suck Kang, Kyoung Nam Kim, Byung Ho Choi |
---|---|
Rok vydání: | 1995 |
Předmět: |
Adult
Male Adolescent Treatment outcome Dentistry Fracture site Pilot Projects Mandibular angle Statistics Nonparametric Fracture Fixation Internal Fixation (surgical) stomatognathic system Mandibular Fractures Bone plate Fracture fixation Humans Medicine General Dentistry Aged business.industry Middle Aged Stable fixation stomatognathic diseases Treatment Outcome Otorhinolaryngology Female Surgery Oral Surgery business Bone Plates |
Zdroj: | Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology. 79:692-695 |
ISSN: | 1079-2104 |
Popis: | More stable fixation and greater resistance against infection are achieved in mandibular angle fractures if the two-miniplate-fixation technique is used. One plate is applied at the superior border and a second plate is applied at the inferior border of the buccal cortex. Strong support for this argument was demonstrated in these in vitro and pilot clinical studies. It is concluded that the two-miniplate-fixation technique is indicated in cases of mandibular angle fracture to achieve stability of the fracture site and early mobility of the jaw. |