Air Displacement Plethysmography, Dual-Energy X-ray Absorptiometry, and Total Body Water to Evaluate Body Composition in Preschool-Age Children
Autor: | Narain Armbya, Aline Andres, Mario A. Cleves, Tina Crook, Thomas M. Badger |
---|---|
Rok vydání: | 2012 |
Předmět: |
Male
Body water Sensitivity and Specificity Cohort Studies Absorptiometry Photon Body Water Humans Medicine Prospective Studies Deuterium Oxide Dual-energy X-ray absorptiometry Whole-body air displacement plethysmography Preschool child Nutrition and Dietetics medicine.diagnostic_test business.industry Air Reproducibility of Results General Medicine Anthropometry Plethysmography Cross-Sectional Studies Concordance correlation coefficient Adipose Tissue Child Preschool Body Composition Female business Nuclear medicine Body mass index Food Science Pediatric population |
Zdroj: | Journal of the Academy of Nutrition and Dietetics. 112:1993-1998 |
ISSN: | 2212-2672 |
DOI: | 10.1016/j.jand.2012.08.020 |
Popis: | Anthropometrics and body mass index are only proxies in the evaluation of adiposity in the pediatric population. Air displacement plethysmography technology was not available for children aged 6 months to 9 years until recently. Our study was designed to test the precision of air displacement plethysmography (ADP) in measuring body fat mass in children at ages 3 to 5 years compared with a criterion method, deuterium oxide dilution (D 2 O), which estimates total body water and a commonly used methodology, dual-energy x-ray absorptiometry (DXA). A prospective, cross-sectional cohort of 66 healthy children (35 girls) was recruited in the central Arkansas region between 2007 and 2009. Weight and height were obtained using standardized procedures. Fat mass (%) was measured using ADP, DXA, and D 2 O. Concordance correlation coefficient and Bland-Altman plots were used to investigate the precision of the ADP techniques against D 2 O and DXA in children at ages 3 to 5 years. ADP concordance correlation coefficient for fat mass was weak (0.179) when compared with D 2 O. Bland-Altman plots revealed a low accuracy and large scatter of ADP fat mass (%) results (mean=−2.5, 95% CI −20.3 to 15.4) compared with D 2 O. DXA fat mass (%) results were more consistent although DXA systematically overestimated fat mass by 4% to 5% compared with D 2 O. Compared with D 2 O, ADP does not accurately assess percent fat mass in children aged 3 to 5 years. Thus, D 2 O, DXA, or quantitative nuclear magnetic resonance may be considered better options for assessing fat mass in young children. |
Databáze: | OpenAIRE |
Externí odkaz: |