Does ceramic translucency affect the degree of conversion of luting agents?
Autor: | William M. Palin, Andrea Soares Quirino, Larissa Maria Cavalcante, Ricardo Huver de Jesus, Luis Felipe Jochims Schneider, Vinícius Esteves Salgado |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2020 |
Předmět: |
Materials science
Polymers and Plastics Opacity Dental materials medicine.medical_treatment 0206 medical engineering Composite number 02 engineering and technology lcsh:Chemical technology Prosthodontics Light curing 03 medical and health sciences 0302 clinical medicine Materials Chemistry medicine Flowable Composite Dentistry (miscellaneous) lcsh:TP1-1185 Ceramic Composite material Curing (chemistry) Cement Luting resins 030206 dentistry 020601 biomedical engineering Surfaces Coatings and Films lcsh:RK1-715 visual_art lcsh:Dentistry Veneers visual_art.visual_art_medium Veneer |
Zdroj: | Applied Adhesion Science, Vol 8, Iss 1, Pp 1-10 (2020) |
ISSN: | 2196-4351 |
DOI: | 10.1186/s40563-020-00127-2 |
Popis: | Objectives Solely light-activated luting agents have been suggested for cementing procedures with aesthetic rehabilitations, but questions remain regarding their curing potential under more opaque prosthesis. To determine the degree of carbon double bond (C=C) conversion (DC) of four categories of luting strategies when considering the interposition of lithium-disilicate ceramic laminates with different translucencies during the photo-activation procedures. Materials and methods Four different luting strategies were considered: a dual-activated resin-based cement (control, RelyX ARC, 3M ESPE), a solely light-activated resin-based cement (RelyX Veneer, 3M ESPE), a flowable resin-based composite (Filtek Z350 XT Flow, 3M ESPE), and a pre-heated (68 °C for 30 min) regular resin-based composite (Filtek Z350 XT, 3M ESPE). The DC was determined by Fourier-transformed infrared spectroscopy (n = 6), 1 min after light-activation in two conditions: (a) with direct light exposure and (b) with light exposure with the interposition of lithium-disilicate disks (e.max Press, Ivoclar Vivadent) with 1.5 mm thickness with three translucent degrees: high translucency (HT), low translucency (LT), and medium opacity (MO). The translucency parameter (TP) formula was performed to quantitatively evaluate the ceramics’ translucencies using white (L* = 93.7, a* = 1.2, and b* = 0.8) and black (L* = 8.6, a* = − 0.7, and b* = − 1.5) backgrounds. The irradiance from the light curing unit (Bluephase G2, Ivoclar Vivadent) was calculated with a power meter (Ophir Optronics) with direct light exposure to the sensor and also with the interposition of the light ceramic discs. Degree of conversion data was submitted to two-way ANOVA and Tukey’s test (α = 0.05). Results Translucency parameters values were 16.4, 13.4 and 12.6 for HT, LT and MO ceramics—respectively—and affected the percentage of light transmission. For all ceramic translucencies the highest DC values were observed for the dual-activated resin-based cement followed by the solely light-activated resin-based cement, the flowable composite and then by pre-heated regular composite. The ceramic’s translucency influenced the DC only for the pre-heated composite. Conclusions The effect of the ceramic translucency on the curing behavior was dependent on the luting strategy. The DC was only affected for the pre-heated composite, which demonstrates lower conversion with the increased ceramic opacity. |
Databáze: | OpenAIRE |
Externí odkaz: |