How to Reduce the Risk of Arteriovenous Fistula Dysfunction by Observing Prepump Arterial Pressure during Hemodialysis: A Multicenter Retrospective Study
Autor: | Ya-Wen Mo, Ying-Gui Chen, Shu-Qian Zheng, Guan-Rong Zhang, Li Song, Xia Fu, Xiao-Wei Han, Li-Fang Zhou, Chun-Yan Sun, Li-Juan Lan |
---|---|
Rok vydání: | 2021 |
Předmět: |
Adult
Male Risk medicine.medical_specialty medicine.medical_treatment 030232 urology & nephrology Arteriovenous fistula 030204 cardiovascular system & hematology 03 medical and health sciences 0302 clinical medicine Renal Dialysis Risk Factors Internal medicine medicine Humans Arterial Pressure Aged Proportional Hazards Models Retrospective Studies business.industry Hazard ratio Retrospective cohort study Hematology General Medicine Blood flow Middle Aged medicine.disease Thrombosis Stenosis Blood pressure Nephrology Arteriovenous Fistula Cardiology Female Hemodialysis business |
Zdroj: | Blood Purification. 50:800-807 |
ISSN: | 1421-9735 0253-5068 |
Popis: | Objective: Prepump arterial (Pa) pressure indicates the ease or difficulty with which the blood pump can draw blood from the vascular access (VA) during hemodialysis. Some studies have suggested that the absolute value of the Pa pressure to the extracorporeal blood pump flow (Qb) ratio set on the machine (|Pa/Qb|) can reflect the dysfunction of VA. This study was conducted to explore the impact of arteriovenous fistula (AVF) dysfunction and to explore the clinical reference value of |Pa/Qb|. Methods: We retrospectively identified adults who underwent hemodialysis at 3 hospitals. Data were acquired from electronic health records. We evaluated the pattern of the association between |Pa/Qb| and AVF dysfunction during 1 year using a Cox proportional hazards regression model with restricted cubic splines. Then, the patients were grouped based on the results, and hazard ratios were compared for different intervals of |Pa/Qb|. Results: A total of 490 patients were analyzed, with an average age of 55 (44, 66) years. There were a total of 85 cases of AVF dysfunction, of which 50 cases were stenosis and 35 cases were thrombosis. There was a U-shaped association between |Pa/Qb| and the risk of AVF dysfunction (p for nonlinearity 0.52 increased the risk of AVF dysfunction. Compared with the group with a |Pa/Qb| value between 0.30 and 0.52, the groups with |Pa/Qb| 0.52 had a 4.04-fold (p = 0.002) and 3.41-fold (p < 0.001) greater risk of AVF dysfunction, respectively. Conclusions: The appropriate range of |Pa/Qb| is between 0.30 and 0.52. When |Pa/Qb| is 0.52, the patient’s AVF function or Qb setting should be reevaluated to prevent subsequent failure. |
Databáze: | OpenAIRE |
Externí odkaz: |