Diagnostic performance of CT and its key signs for COVID-19: A systematic review and meta-analysis

Autor: Zhenxi Zhang, Wanyue Qin, Yuhui Zhong, Xiuting Wu, Kai Li
Jazyk: angličtina
Rok vydání: 2020
Předmět:
DOI: 10.1101/2020.05.24.20111773
Popis: PurposeTo evaluate the diagnostic value of chest CT in 2019 novel coronavirus disease (COVID-19), using the reverse transcription polymerase chain reaction (RT-PCR) as a reference standard. At the same time, the imaging features of CT in confirmed COVID-19 patients would be summarized.MethodsA comprehensive literature search of 5 electronic databases was performed. The pooled sensitivity, specificity, positive predictive value, and negative predictive value were calculated using the random-effects model and the summary receiver operating characteristic (SROC) curve. We also conducted a meta-analysis to estimate the pooled incidence of the chest CT imaging findings and the 95% confidence interval (95%CI). Meta-regression analysis was used to explore the source of heterogeneity.ResultsOverall, 25 articles comprising 4,857 patients were included. The pooled sensitivity of CT was 93% (95% CI, 89-96%) and specificity was 44% (95% CI, 27-62%). The area under the SROC curve was 0.94 (95% CI, 0.91-0.96). For the RT-PCR assay, the pooled sensitivity of the initial test and the missed diagnosis rate after the second-round test were 76% (95% CI: 59-89%; I2=96%) and 26% (95% CI: 14-39%; I2=45%), respectively. According to the subgroup analysis, the diagnostic sensitivity of CT in Hubei was higher than that in other regions. Besides, the most common patterns on CT imaging finding was ground glass opacities (GGO) 58% (95% CI: 49-70%), followed by air bronchogram 51% (95% CI: 31-70%). Lesions were inclined to distribute in peripheral 64% (95% CI: 49-78%), and the incidence of bilateral lung involvement was 69% (95% CI: 58-79%).ConclusionsThere were still several cases of missed diagnosis after multiple RT-PCR examinations. In high-prevalence areas, CT could be recommended as an auxiliary screening method for RT-PCR.Key pointsTaking RT-PCR as the reference standard, the pooled sensitivity of CT was 93% (95% CI, 89-96%) and the specificity was 44% (95% CI, 27-62%). The area under the SROC curve was 0.94 (95% CI, 0.91-0.96).For the RT-PCR assay, the pooled sensitivity of the initial test and the missed diagnosis rate after the second-round test were 76% (95% CI: 59-89%) and 26% (95% CI: 14-39%), respectively.GGO was the key sign of the CT imaging, with an incidence of 58% (95% CI: 49-70%) in patients with SARS-CoV-2 infection. Pneumonia lesions were inclined to distribute in peripheral 64% (95% CI: 49-78%) and bilateral 69% (95% CI: 58-79%) lung lobes.
Databáze: OpenAIRE