Non-coplanar VMAT combined with non-uniform dose prescription markedly reduces lung dose in breath-hold lung SBRT
Autor: | Natallia Prakofyeva, Anna Simeonova-Chergou, Jens Fleckenstein, Kerstin Siebenlist, Frederik Wenz, Frank Lohr, Judit Boda-Heggemann, Tanya Gudzheva |
---|---|
Rok vydání: | 2018 |
Předmět: |
Adult
Intensity-modulated radiotherapy Lung neoplasms Non-small-cell lung carcinoma Radiotherapy planning Stereotactic radiotherapy Radiology Nuclear Medicine and Imaging Oncology Lung Neoplasms medicine.medical_treatment Planning target volume Radiosurgery 030218 nuclear medicine & medical imaging Breath Holding 03 medical and health sciences 0302 clinical medicine Carcinoma Non-Small-Cell Lung medicine Humans Radiology Nuclear Medicine and imaging Lung volumes Radiation treatment planning Lung Aged business.industry Radiotherapy Planning Computer-Assisted Radiotherapy Dosage Middle Aged Volumetric modulated arc therapy Dose prescription Tumor Burden Radiation therapy Survival Rate medicine.anatomical_structure 030220 oncology & carcinogenesis Female Dose Fractionation Radiation Radiotherapy Intensity-Modulated Nuclear medicine business Non coplanar |
Zdroj: | Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al]. 194(9) |
ISSN: | 1439-099X |
Popis: | In this retrospective treatment planning study, the effect of a uniform and non-uniform planning target volume (PTV) dose coverage as well as a coplanar and non-coplanar volumetric modulated arc therapy (VMAT) delivery approach for lung stereotactic body radiation therapy (SBRT) in deep inspiration breath-hold (DIBH) were compared. For 46 patients with lesions in the peripheral lungs, three different treatment plans were generated: First, a coplanar 220° VMAT sequence with a uniform PTV dose prescription (UC). Second, a coplanar 220° VMAT treatment plan with a non-uniform dose distribution in the PTV (nUC). Third, a non-coplanar VMAT dose delivery with four couch angles (0°, ±35°, 90°) and a non-uniform prescription (nUnC) was used. All treatment plans were optimized for pareto-optimality with respect to PTV coverage and ipsilateral lung dose. Treatment sequences were delivered on a flattening-filter-free linear accelerator and beam-on times were recorded. Dosimetric comparison between the three techniques was performed. For the three scenarios (UC, nUC, nUnC), median gross tumor volume (GTV) doses were 63.4 ± 2.5, 74.4 ± 3.6, and 77.9 ± 3.8 Gy, and ipsilateral V10Gy lung volumes were 15.7 ± 6.1, 13.9 ± 4.7, and 12.0 ± 5.1%, respectively. Normal tissue complication probability of the ipsilateral lung was 3.9, 3.1, and 2.8%, respectively. The number of monitor units were 5141 ± 1174, 4104 ± 786, and 3657 ± 710 MU and the corresponding beam-on times were 177 ± 54, 143 ± 29, and 148 ± 26 s. For SBRT treatments in DIBH, a non-uniform dose prescription in the PTV, combined with a non-coplanar VMAT arc arrangement, significantly spares the ipsilateral lung while increasing dose to the GTV without major treatment time increase. |
Databáze: | OpenAIRE |
Externí odkaz: |