Age Effects of Bone Conduction Vibration Vestibular-evoked Myogenic Potentials (VEMPs) Using B81 and Impulse Hammer Stimuli
Autor: | Kristen L. Janky, Jessie N. Patterson, Katherine R. Gordon, Julie A. Honaker, Amanda I. Rodriguez |
---|---|
Rok vydání: | 2021 |
Předmět: |
Adult
medicine.medical_specialty Adolescent Vestibular evoked myogenic potential Stimulus (physiology) Impulse (physics) Audiology Vibration Article Young Adult Speech and Hearing Bone conduction Hearing medicine Humans Child Aged Aged 80 and over Vestibular system Air conduction business.industry Extramural Response characteristics Middle Aged Vestibular Evoked Myogenic Potentials Otorhinolaryngology business Bone Conduction |
Zdroj: | Ear Hear |
ISSN: | 0196-0202 |
DOI: | 10.1097/aud.0000000000001024 |
Popis: | Objective Recently developed, the Radioear B81 bone oscillator allows for higher bone conduction vibration output; however, normative data are lacking regarding its use in vestibular-evoked myogenic potential (VEMP) testing. The purpose of this study was to examine the effect of age on cervical and ocular VEMP (c- and oVEMP) responses using the B81 and to compare with air conduction stimuli (ACS) and impulse hammer (IH) VEMP response characteristics. Design c- and oVEMP were completed with ACS, B81, and IH stimuli in healthy participants (age range = 10 to 87 years, n = 85). Results Regardless of stimulus type, c- and oVEMP amplitudes and response rates decreased with age. For cVEMP response rates, ACS performed better or equal to B81, which was superior to the IH. For cVEMP corrected amplitude, ACS had significantly higher amplitudes compared with B81 and IH. There was no difference in cVEMP corrected amplitude between B81 and IH. For oVEMP, response rates were comparable between stimuli with the largest disparity in response rates occurring in the oldest groups where IH outperformed both ACS and B81. For oVEMP amplitude, IH had significantly higher amplitudes compared with B81 and ACS. There was no difference in oVEMP amplitude between B81 and ACS. Conclusions Age significantly affected c- and oVEMP amplitudes regardless of stimulus type (ACS, B81, IH). All stimuli are appropriate for eliciting c- and oVEMP in the young individuals. While ACS resulted in higher cVEMP corrected amplitudes, either ACS or B81 are appropriate for older individuals. However, for oVEMPs, higher response rates and larger amplitudes were noted for IH followed by B81 and ACS. Overall, the B81 performed well across the lifespan for c- and oVEMPs and may be a reasonable bone conduction vibration option for patients with absent ACS VEMPs, but at this time is not recommended as a replacement to ACS. |
Databáze: | OpenAIRE |
Externí odkaz: |