Arterial flow patterns in healthy transitioning near-term neonates
Autor: | Prashanth Murthy, John V. Tyberg, Sharandeep Kaur, Sarah Howell, Amelie Stritzke, Zhiying Liang, Verena Kuret |
---|---|
Rok vydání: | 2019 |
Předmět: |
medicine.medical_specialty
Kidney business.industry Hemodynamics 030204 cardiovascular system & hematology 03 medical and health sciences 0302 clinical medicine medicine.anatomical_structure Internal medicine medicine.artery Ductus arteriosus Pediatrics Perinatology and Child Health medicine Vascular resistance Cardiology Gestation 030212 general & internal medicine Superior mesenteric artery Neonatology business Perfusion Artery |
Zdroj: | BMJ Paediatrics Open |
ISSN: | 2399-9772 |
DOI: | 10.1136/bmjpo-2018-000333 |
Popis: | ObjectiveSignificant haemodynamic changes occur at delivery impacting organ blood flow distribution. We aimed to characterise Doppler indices patterns over time in three different organs (brain, gut and kidney) and test them as measures of vascular resistance.DesignObservational cohort study. Serial Doppler interrogations of the anterior cerebral, superior mesenteric and renal arteries within 2 hours, 2–6, and 24 hours of life, in combination with central haemodynamic data.PatientsHealthy, near-term (>36 weeks of gestation) neonates.Outcome measuresPulsatility (PI) and Resistance Indices (RI) patterns and organ-specific conductances, detailed echocardiographic haemodynamic measures.ResultsTwenty-one babies were studied. Doppler morphology and adaptation patterns were distinctly different between the organs (brain, gut and kidney) supporting autonomous vascular regulatory effects. The PI differentiated especially between kidney and other organ flow consistently over time. PI and RI for all three organs decreased. The variance in organ conductance did not explain the variance in 1/PI, indicating that PI is not a measure of resistance. Superior mesenteric artery had the highest velocity with 72 cm/s. Non-invasively acquired pilot serial values in a normal population are given. Patent ductus arteriosus flow remained open at discharge for 36%.ConclusionsHaemodynamic transitioning patterns assessed by serial Dopplers in healthy near-term neonates differ in brain, gut and kidney: Doppler waveform morphology differs, and PI differentiates renal Doppler morphology, compared with the other organs. While PI and RI decline for all organs, they do not measure resistance. Brain artery velocity increases, mesenteric perfusion is variable and renal Vmax decreases. |
Databáze: | OpenAIRE |
Externí odkaz: |