Radiomics in the evaluation of lung nodules: Intrapatient concordance between full-dose and ultra-low-dose chest computed tomography

Autor: Cédric Hintzpeter, Michael E. Calhoun, Pierre-Alexis Autrusseau, Ilya G. Goldberg, Pierre De Marini, Aissam Labani, Mickaël Ohana, Anne-Claire Ortlieb, Pierre Leyendecker, Catherine Roy
Přispěvatelé: Les Hôpitaux Universitaires de Strasbourg (HUS), Institut Paoli-Calmettes, Fédération nationale des Centres de lutte contre le Cancer (FNCLCC), Laboratoire des sciences de l'ingénieur, de l'informatique et de l'imagerie (ICube), École Nationale du Génie de l'Eau et de l'Environnement de Strasbourg (ENGEES)-Université de Strasbourg (UNISTRA)-Institut National des Sciences Appliquées - Strasbourg (INSA Strasbourg), Institut National des Sciences Appliquées (INSA)-Institut National des Sciences Appliquées (INSA)-Institut National de Recherche en Informatique et en Automatique (Inria)-Les Hôpitaux Universitaires de Strasbourg (HUS)-Centre National de la Recherche Scientifique (CNRS)-Matériaux et Nanosciences Grand-Est (MNGE), Université de Strasbourg (UNISTRA)-Université de Haute-Alsace (UHA) Mulhouse - Colmar (Université de Haute-Alsace (UHA))-Institut National de la Santé et de la Recherche Médicale (INSERM)-Institut de Chimie du CNRS (INC)-Centre National de la Recherche Scientifique (CNRS)-Université de Strasbourg (UNISTRA)-Université de Haute-Alsace (UHA) Mulhouse - Colmar (Université de Haute-Alsace (UHA))-Institut National de la Santé et de la Recherche Médicale (INSERM)-Institut de Chimie du CNRS (INC)-Centre National de la Recherche Scientifique (CNRS)-Réseau nanophotonique et optique, Université de Strasbourg (UNISTRA)-Université de Haute-Alsace (UHA) Mulhouse - Colmar (Université de Haute-Alsace (UHA))-Centre National de la Recherche Scientifique (CNRS)-Université de Strasbourg (UNISTRA)-Centre National de la Recherche Scientifique (CNRS)
Jazyk: angličtina
Rok vydání: 2021
Předmět:
Zdroj: Diagnostic and Interventional Imaging
Diagnostic and Interventional Imaging, 2021, 102 (4), ⟨10.1016/j.diii.2021.01.010⟩
ISSN: 2211-5684
Popis: Purpose: The purpose of this study was to retrospectively evaluate the quantitative and qualitative intrapatient concordance of pulmonary nodule risk assessment by commercially available radiomics software between full-dose (FD) chest-CT and ultra-low-dose (ULD) chest CT.Materials and methods: Between July 2013 and September 2015, 68 patients (52 men and16 women; mean age, 65.5±10.6 [SD] years; range: 35-87 years) with lung nodules≥5mm and0.9) or "undetermined" (0.1≤mSI≤0.9). Intrapatient qualitative agreement was evaluated with weighted Cohen-Kappa test and quantitative agreement with intraclass correlation coefficient (ICC).Results: Ninety-nine lung nodules with a mean size of 9.14±4.3 (SD) mm (range: 5-25mm) in 68 patients (mean 1.46 nodule per patient; range: 1-5) were assessed; mean mSI was 0.429±0.331 (SD) (range: 0.001-1) with FD chest CT (22/99 [22%] "benign-like", 67/99 [68%] "undetermined" and 10/99 [10%] "malignant-like") and mean mSI was 0.487±0.344 (SD) (range: 0.002-1) with ULD chest CT (20/99 [20%] "benign-like", 59/99 [60%] "undetermined" and 20/99 [20%] "malignant-like"). Qualitative and quantitative agreement of FD chest CT with ULD chest CT were "good" with Kappa value of 0.60 (95% CI: 0.46-0.74) and ICC of 0.82 (95% CI: 0.73-0.87), respectively.Conclusion: A good agreement in malignancy similarity index can be obtained between ULD chest CT and FD chest CT using radiomics software. However, further studies must be done with more case material to confirm our results and elucidate the diagnostic capabilities of radiomics software using ULD chest CT for lung nodule characterization by comparison with FD chest CT.
Databáze: OpenAIRE