Ultrasonography-guided scleral buckle retinopexy and cryotherapy: case report

Autor: Daniel da Rocha Lucena, L. R. Lucena, Jefferson Augusto Santana Ribeiro, Marco S. Folgosa, Rodrigo Jorge
Rok vydání: 2008
Předmět:
Zdroj: Arquivos Brasileiros de Oftalmologia v.72 n.2 2009
Arquivos brasileiros de oftalmologia
Conselho Brasileiro de Oftalmologia (CBO)
instacron:CBO
ISSN: 1678-2925
Popis: If the ocular media are clear, indirect binocular ophthalmoscopy allows retinal detachment and retinal tear identification and treatment under direct visualization. However, if opacities are present preventing direct fundus examination, ultrasonography becomes the most important tool for evaluating the posterior segment. In addition, ultrasonography can be useful in retinal tear treatment by guiding cryotherapy. In this article we describe a rhegmatogenous retinal detachment treatment technique applied to a patient with corneal opacity. Cryopexy and circumferential and radial buckle positioning were guided by ultrasonography, resulting in retinal attachment during the 6-month follow-up period.