Investigation of the neutron-gamma ray discrimination performance at low neutron energy of a solution-grown stilbene scintillator
Autor: | Brian Stout, Robert Jacqmin, Michael Petit, V. Gressier, Augusto Di Chicco |
---|---|
Přispěvatelé: | CEA-Direction des Energies (ex-Direction de l'Energie Nucléaire) (CEA-DES (ex-DEN)), Commissariat à l'énergie atomique et aux énergies alternatives (CEA), Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Institut FRESNEL (FRESNEL), Aix Marseille Université (AMU)-École Centrale de Marseille (ECM)-Centre National de la Recherche Scientifique (CNRS), Centre National de la Recherche Scientifique (CNRS)-École Centrale de Marseille (ECM)-Aix Marseille Université (AMU) |
Jazyk: | angličtina |
Rok vydání: | 2019 |
Předmět: |
Materials science
[PHYS.NUCL]Physics [physics]/Nuclear Theory [nucl-th] Physics::Instrumentation and Detectors Astrophysics::High Energy Astrophysical Phenomena QC1-999 solution-grown stilbene Mono-energetic neutrons Scintillator [PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex] 030218 nuclear medicine & medical imaging Solution-grownstilbene Organic scintillators 03 medical and health sciences Time of flight 0302 clinical medicine Data acquisition Optics Neutron Digital acquisition system PSD ComputingMilieux_MISCELLANEOUS Range (particle radiation) business.industry Physics 05 social sciences Detector Gamma ray 050301 education Neutron temperature AMANDE facility business 0503 education |
Zdroj: | ANIMMA 2019-International conference on Advancements in Nuclear Instrumentation Measurement Methods and their Applications ANIMMA 2019-International conference on Advancements in Nuclear Instrumentation Measurement Methods and their Applications, Jun 2019, Portoro, Slovenia EPJ Web of Conferences, Vol 225, p 04013 (2020) ANIMMA 2019 ANIMMA 2019, Jun 2019, Portoro, Slovenia |
Popis: | The results of experiments performed with a Ø25 x 25 mm solution-grown stilbene crystal in mono-energetic neutron fields in the 80-to-230 keV energy range are presented. The goal of the measurements, performed at the AMANDE facility, was to explore the capabilities of this organic scintillator to measure neutrons at the lowest possible energy with good pulse shape discrimination (PSD). The time of flight (TOF) technique was used in order to help with the neutron-gamma discrimination. The data are collected via a programmable digital acquisition (DAQ) system CAEN DT7530 using the software CoMPASS with the charge comparison method (CCM). The data are analysed using post-processing codes developed in the ROOT environment. The results show that the stilbene detector has discrimination capabilities for energies as low as 80 keV. |
Databáze: | OpenAIRE |
Externí odkaz: |