Curved single-plane clear corneal incision made under anterior chamber collapse by aqueous humor aspiration prevents leakage after cataract surgery

Autor: Masahiro Zako, Kyoichi Mizumoto, Masahiko Gosho
Rok vydání: 2019
Předmět:
Zdroj: International ophthalmology. 40(7)
ISSN: 1573-2630
Popis: To evaluate the self-sealing on curved single-plane clear corneal incisions (CCIs) after cataract surgery. The collapse of the anterior chamber was made by aspirating the aqueous humor in order to make curved single-plane CCI. A retrospective study was conducted at Asai Hospital in Japan. There were 189 eyes of 132 patients scheduled from February to April 2017 for single-plane CCI. There were 175 eyes of 128 patients from February to April 2018 for curved single-plane CCI. Curved single-plane CCIs were made with aqueous humor aspiration via aqueous humor pipette, and single-plane CCIs were made without the aspiration. In case of leakage of aqueous humor from the CCI at the end of surgery, sutures were used. The main outcome measure was the proportion of sutures for CCI. Secondary outcomes included CCI length and surgically induced astigmatism (SIA) magnitude. The proportions of suture in single-plane CCI and in curved single-plane CCIs were 25.4% (48/189) and 0% (0/175), respectively (p
Databáze: OpenAIRE