Optimization of automatic bolus tracking for timing of the arterial phase of helical liver CT

Autor: Joern J.W. Sandstede, G. Wittenberg, Dietbert Hahn, A. Tschammler, Meinrad Beer, Carsten Vogelsang
Rok vydání: 2001
Předmět:
Zdroj: European radiology. 11(8)
ISSN: 0938-7994
Popis: The aim of this study was to optimize bolus tracking for timing of the arterial phase of biphasic helical liver CT and to compare optimized bolus tracking to a standard delay. One hundred fifty patients were examined with six protocols: 5- or 10-s delay after triggering at a threshold of 50 or 75 or 100 HU enhancement in the aorta at the origin of the celiac arteries after injection of 120 ml contrast material at 3 ml/s. Optimal arterial enhancement was defined as 20-30% of hepatic enhancement in portal venous phase. Another 50 patients were examined with the optimized protocol and compared to 50 gender- and age-matched patients who underwent a 25-s standard delay. A 10-s delay after the 75-HU threshold resulted in the most patients with an optimal arterial phase (p0.01). Thirty-one of 75 patients examined with this protocol showed optimal early liver enhancement. Bolus tracking compared with standard delay revealed only a trend for a difference (p = 0.07). The outcome of automatic bolus tracking differs depending on the protocol used; however, optimal arterial phase imaging was seen in only 41% of patients, indicating only a trend for superior timing compared with a standard delay.
Databáze: OpenAIRE