Fundus Oculi Glaucoma Health Informatics Fundus (eye) Sensitivity and Specificity Displacement (vector) Retina Position (vector) Image Interpretation Computer-Assisted medicine Image Processing Computer-Assisted Humans Computer vision business.industry Centroid Retinal Vessels Vascular bundle medicine.disease Computer Science Applications medicine.anatomical_structure Normal position Artificial intelligence business Optic disc |
Zdroj: | Computers in biology and medicine. 47 |
ISSN: | 1879-0534 |
Popis: | This paper presents a methodology for glaucoma detection based on measuring displacements of blood vessels within the optic disc (vascular bundle) in human retinal images. The method consists of segmenting the region of the vascular bundle in an optic disc to set a reference point in the temporal side of the cup, determining the position of the centroids of the superior, inferior, and nasal vascular bundle segmented zones located within the segmented region, and calculating the displacement from normal position using the chessboard distance metric. The method was successful in 62 images out of 67, achieving 93.02% sensitivity, 91.66% specificity, and 91.34% global accuracy in pre-diagnosis. |