Harmonic motion imaging for abdominal tumor detection and high-intensity focused ultrasound ablation monitoring: an in vivo feasibility study in a transgenic mouse model of pancreatic cancer
Autor: | Kenneth P. Olive, Gary Y. Hou, Carmine F. Palermo, Elisa E. Konofagou, Hong Chen, Thomas Payen, Yang Han |
---|---|
Rok vydání: | 2015 |
Předmět: |
Materials science
Acoustics and Ultrasonics medicine.medical_treatment Mice Transgenic Simple harmonic motion Article Mice Pancreatic tumor In vivo Pancreatic cancer medicine Image Processing Computer-Assisted Animals Electrical and Electronic Engineering Instrumentation Ultrasonography Signal Processing Computer-Assisted Ablation medicine.disease High-intensity focused ultrasound Pancreatic Neoplasms Transducer Abdominal tumor Feasibility Studies High-Intensity Focused Ultrasound Ablation Biomedical engineering |
Zdroj: | IEEE transactions on ultrasonics, ferroelectrics, and frequency control. 62(9) |
ISSN: | 1525-8955 |
Popis: | Harmonic motion imaging (HMI) is a radiationforce- based elasticity imaging technique that tracks oscillatory tissue displacements induced by sinusoidal ultrasonic radiation force to assess the resulting oscillatory displacement denoting the underlying tissue stiffness. The objective of this study was to evaluate the feasibility of HMI in pancreatic tumor detection and high-intensity focused ultrasound (HIFU) treatment monitoring. The HMI system consisted of a focused ultrasound transducer, which generated sinusoidal radiation force to induce oscillatory tissue motion at 50 Hz, and a diagnostic ultrasound transducer, which detected the axial tissue displacements based on acquired radio-frequency signals using a 1-D cross-correlation algorithm. For pancreatic tumor detection, HMI images were generated for pancreatic tumors in transgenic mice and normal pancreases in wild-type mice. The obtained HMI images showed a high contrast between normal and malignant pancreases with an average peak-to-peak HMI displacement ratio of 3.2. Histological analysis showed that no tissue damage was associated with HMI when it was used for the sole purpose of elasticity imaging. For pancreatic tumor ablation monitoring, the focused ultrasound transducer was operated at a higher acoustic power and longer pulse length than that used in tumor detection to simultaneously induce HIFU thermal ablation and oscillatory tissue displacements, allowing HMI monitoring without interrupting tumor ablation. HMI monitoring of HIFU ablation found significant decreases in the peak-to-peak HMI displacements before and after HIFU ablation with a reduction rate ranging from 15.8% to 57.0%. The formation of thermal lesions after HIFU exposure was confirmed by histological analysis. This study demonstrated the feasibility of HMI in abdominal tumor detection and HIFU ablation monitoring. |
Databáze: | OpenAIRE |
Externí odkaz: |