Assessment of quality and interpretation of panoramic radiographs obtained in the Lao People's Democratic Republic as part of a teleradiology collaboration with Japan

Autor: Toshihiro Suzuki, Kichibee Otsuka, Ichiro Nakajima, Fumiyuki Kuwata, Shigeharu Hosono, Souksavanh Vongsa, Ken-ichiro Ejima, Kunihito Matsumoto, Hirofumi Aboshi, Kiyomi Kohinata
Rok vydání: 2015
Předmět:
Zdroj: Journal of oral science. 57(3)
ISSN: 1880-4926
Popis: As part of quality assessment of a teleradiology program we evaluated the validity of patient information received, the quality of panoramic radiography imaging in Laos, and the ability of a Laotian radiologist to detect temporomandibular joint abnormalities. The amount of patient information gathered from 2,021 scans of panoramic radiographs was evaluated by triage before image diagnosis. Among the radiographs from 2,021 patients, primary triage indicated that there was insufficient information for 794 (39.3%) patients. Secondary triage to assess imaging failure included 1,227 radiographs, four of which were excluded from imaging diagnosis because of unacceptable image flaws. In total, 2,446 joints from 1,223 radiographs were evaluated for temporomandibular joint abnormalities in order to compare the image interpretation abilities of Laotian and Japanese radiologists. The kappa coefficient was 0.836 (P < 0.01) for the agreement between the two observers in detecting temporomandibular joint abnormalities on radiographs. We conclude that additional efforts are needed in order to overcome the challenges of maintaining quality in imaging techniques and diagnoses in Laos.
Databáze: OpenAIRE