Biaxial bending of SFRC slabs: Is conventional reinforcement necessary?
Autor: | Marco di Prisco, Matteo Colombo, Ali Pourzarabi |
---|---|
Rok vydání: | 2018 |
Předmět: |
Ultimate load
Serviceability and ultimate behaviour Slabs Materials science Biaxial bending Ductility Fibre reinforced concrete Reinforcement efficiency Civil and Structural Engineering Building and Construction Materials Science (all) Mechanics of Materials 0211 other engineering and technologies 02 engineering and technology Load carrying Strength of materials Cracking Deflection (engineering) 021105 building & construction Solid mechanics General Materials Science Bearing capacity Composite material Reinforcement |
Zdroj: | Materials and Structures. 52 |
ISSN: | 1871-6873 1359-5997 |
DOI: | 10.1617/s11527-018-1302-0 |
Popis: | Fibre reinforced concrete shows enhanced performance in statistically redundant bi-dimensional structural elements that undergo biaxial bending. However, the lack of reinforcing rebars in fibre reinforced structural elements may affect the structural ductility which may further affect the overall load bearing capacity of these structures. To investigate the influence of fibres in such elements, six concrete plates of 2000 × 2000 × 150 mm reinforced with steel fibres and/or reinforcing rebars are tested under a central concentrated load. Two of the elements are reinforced with only 35 kg/m3 of steel fibres, two are reinforced with 2-way conventional reinforcing rebars (35 kg/m3, in each direction) and two are reinforced with both steel fibres and rebars. The specimens are simply supported at the middle of each side by means of a bilateral restraint; the deflection response and cracking behaviour of all the specimens are recorded and compared. Moreover, the methodology introduced in the fib Model Code 2010 for design of steel fibre reinforced concrete is implemented to predict the ultimate load bearing capacity of these elements and its reliability is determined in comparison with the experimental values. The comparison of the behaviour of the specimens reinforced only with steel fibres, with those reinforced with steel rebars, shows the higher efficiency of steel fibres in terms of load carrying capacity, but with a lower ductility. The combination of steel fibres and rebars allows for a better exploitation of the capacity of both reinforcement solutions. Finally, the reliability of the approach implemented for the ultimate load prediction is shown and the need of rebars in providing ductility in fibre reinforced concrete members is underlined. |
Databáze: | OpenAIRE |
Externí odkaz: |