Novel Imprinted Polymer for the Preconcentration of Cadmium with Determination by Inductively Coupled Plasma Mass Spectrometry
Autor: | Vedat Yilmaz, Zikri Arslan, Jerzy Leszczynski, Hayriye Yilmaz |
---|---|
Rok vydání: | 2017 |
Předmět: |
Detection limit
Chromatography Elution 010401 analytical chemistry Biochemistry (medical) Clinical Biochemistry 02 engineering and technology 021001 nanoscience & nanotechnology Mass spectrometry 01 natural sciences Biochemistry Article 0104 chemical sciences Analytical Chemistry chemistry.chemical_compound Monomer Column chromatography Certified reference materials chemistry Electrochemistry Solid phase extraction 0210 nano-technology Inductively coupled plasma mass spectrometry Spectroscopy |
Zdroj: | Analytical letters. 50(3) |
ISSN: | 0003-2719 |
Popis: | A novel Cd(II)-imprinted polymer was prepared with chemical immobilization approach by using N-methacryloyl-L-histidine as a vinylated chelating agent for on-line solid phase extraction of Cd(II) for determination by inductively coupled plasma mass spectrometry. Cd(II)-monomer complex was synthesized and copolymerized via bulk polymerization method in the presence of ethyleneglycoldimethacrylate cross-linker. The resulting polymer was leached with 1.0 mol L-1 HNO3 to generate the cavities in the polymer for Cd(II) ions. The experimental conditions, including load pH, solution flow rate, and eluent concentration for effective sorption of Cd(II) were optimized using a minicolumn of the imprinted polymer. A volume of 5.0 mL sample 5 μg L-1 Cd(II) solution at pH 6.5 was loaded onto the column at 2.0 mL min-1 by using a sequential injection system (FIALab 3200) followed by elution with 1.0 mL of 0.75 mol L-1 HNO3. The relative selectivity coefficients of the imprinted polymer for Cd(II) were 38.5, 3.5, 3.0, 2.5 and 6.0 in the presence of Cu(II), Ni(II), Zn(II), Co(II) and Pb(II), respectively. Computational calculations revealed that the selectivity of the imprinted polymer was mediated by the stability of Cd(II)-N-methacryloyl-L-histidine complex which was far more stable than those of commonly used monomers, such as 4-vinyl pyridine, methacrylic acid and vinylimidazole. The detection limit (3s) and relative standard deviation (%) were found to be 0.004 μg L-1 and 3.2%, respectively. The method was validated by analysis of seawater certified reference material (CASS-4) and successfully applied to the determination of Cd(II) in coastal seawater and estuarine water samples. |
Databáze: | OpenAIRE |
Externí odkaz: | |
Nepřihlášeným uživatelům se plný text nezobrazuje | K zobrazení výsledku je třeba se přihlásit. |