The use of pseudo‐MRM for a sensitive and selective detection and quantification of polycyclic aromatic compounds by tandem mass spectrometry

Autor: Mathieu Galmiche, Anaïs Rodrigues, Estelle Motsch, Olivier Delhomme, Yannis‐Nicolas François, Maurice Millet
Přispěvatelé: Institut de chimie et procédés pour l'énergie, l'environnement et la santé (ICPEES), Université de Strasbourg (UNISTRA)-Institut de Chimie du CNRS (INC)-Centre National de la Recherche Scientifique (CNRS)-Matériaux et Nanosciences Grand-Est (MNGE), Université de Strasbourg (UNISTRA)-Université de Haute-Alsace (UHA) Mulhouse - Colmar (Université de Haute-Alsace (UHA))-Institut National de la Santé et de la Recherche Médicale (INSERM)-Institut de Chimie du CNRS (INC)-Centre National de la Recherche Scientifique (CNRS)-Université de Strasbourg (UNISTRA)-Université de Haute-Alsace (UHA) Mulhouse - Colmar (Université de Haute-Alsace (UHA))-Institut National de la Santé et de la Recherche Médicale (INSERM)-Centre National de la Recherche Scientifique (CNRS), Laboratoire de spectrométrie de masse des interactions et des systèmes, Chimie de la matière complexe (CMC), Université de Strasbourg (UNISTRA)-Institut de Chimie du CNRS (INC)-Centre National de la Recherche Scientifique (CNRS)-Université de Strasbourg (UNISTRA)-Institut de Chimie du CNRS (INC)-Centre National de la Recherche Scientifique (CNRS), Institut de Chimie de Strasbourg, Université de Strasbourg (UNISTRA)-Institut de Chimie du CNRS (INC)-Centre National de la Recherche Scientifique (CNRS), univOAK, Archive ouverte
Jazyk: angličtina
Rok vydání: 2022
Předmět:
Zdroj: Rapid Communications in Mass Spectrometry
Rapid Communications in Mass Spectrometry, 2022, 36 (13), ⟨10.1002/rcm.9307⟩
ISSN: 0951-4198
1097-0231
Popis: Rationale: Multiple Reaction Monitoring (MRM) is a sensitive and selective detection mode for target trace-level analysis. However, it requires the fragmentation of labile bonds which are not present in molecules such as Polycyclic Aromatic Hydrocarbons (PAHs) and their heterocyclic derivatives (PANHs, PASHs).Methods: We present the application of an alternative tandem mass spectrometry (MS/MS) mode called "pseudo-MRM" for the GCMS/MS analysis of Polycyclic Aromatic Compounds (PACs). This mode is based on the monitoring of transitions with no mass loss between the precursor and the product ion. Pseudo-MRM peak areas were compared with those of classic MRM on three different mass spectrometers: two triple quadrupoles and an ion trap.Results: For all non-polar PACs studied here (PAHs, PANHs and PASHs), the pseudo-MRM transition was always the most intense. The classic MRM transitions exhibited peak areas 2 to 5 times lower. On the contrary, for the functionalized PACs (oxygenated and nitrated PAHs), classic MRM was favored over pseudo-MRM. These observations were confirmed on two triple quadrupoles (QqQs), and the real-world applicability of pseudo-MRM on QqQs was validated by the successful analysis of Diesel PM. However, a comparison with an ion trap showed that pseudo-MRM was never favored on that instrument, which caused fragmentation of non-polar PACs in MS/MS.Conclusions: The results of this study show an important gain in sensitivity when using pseudo-MRM instead of MRM for non-polar PACs on QqQ instruments. The selectivity of MRM is preserved in pseudo-MRM by applying non-zero collision energies to which only these non-polar PACs are resistant, not the isobaric interferences. No interference issue was observed when analyzing Diesel PM, a complex matrix, with our pseudo-MRM method. Therefore, we advise for a broader use of this MS/MS mode for trace-level determination of non-polar PAHs.
Databáze: OpenAIRE