Development of a pain monitoring device focused on newborn infant applications: The NeoDoloris project
Autor: | Laurent Storme, Thameur Rakza, Régis Logier, César Boog, Romaric Marcilly, S. Bras da Costa, Laura Butruille, J. De Jonckheere |
---|---|
Přispěvatelé: | Clinical Investigation Center - Innovative Technologies, Institut National de la Santé et de la Recherche Médicale (INSERM)-Centre Hospitalier Régional Universitaire [Lille] (CHRU Lille), CHU Lille, Centre d'Investigation Clinique - Innovation Technologique de Lille - CIC 1403 - CIC 9301 (CIC Lille), Institut National de la Santé et de la Recherche Médicale (INSERM)-Université de Lille-Centre Hospitalier Régional Universitaire [Lille] (CHRU Lille), Evaluation des technologies de santé et des pratiques médicales - ULR 2694 (METRICS), Université de Lille-Centre Hospitalier Régional Universitaire [Lille] (CHRU Lille), Hôpital Jeanne de Flandres, Université de Lille, Droit et Santé-Centre Hospitalier Régional Universitaire [Lille] (CHRU Lille), Environnement périnatal et croissance - EA 4489 (EPS) |
Rok vydání: | 2015 |
Předmět: |
medicine.medical_specialty
Medical staff Neonatal intensive care unit business.industry Biomedical Engineering Biophysics Stimulus (physiology) Infant newborn Autonomic nervous system Physical medicine and rehabilitation Nociception Ambulatory medicine Heart rate variability [SDV.IB]Life Sciences [q-bio]/Bioengineering Intensive care medicine business |
Zdroj: | Innovation and Research in BioMedical engineering Innovation and Research in BioMedical engineering, 2015, 36 (2), pp.80-85. ⟨10.1016/j.irbm.2015.01.005⟩ |
ISSN: | 1959-0318 |
DOI: | 10.1016/j.irbm.2015.01.005 |
Popis: | Heart rate variability (HRV) reflects the autonomic nervous system activity on the organism. Sympathetic and parasympathetic influences in response to painful or stressful stimulus can be measured by the variations of RR intervals. After the elaboration of an automated index evaluating parasympathetic tone in adults (Analgesia Nociception Index, ANI), we choose to adapt this technology to neonates. A work system analysis of the maternity and the neonatal intensive care unit has established the needs for such an application and users' requirements the application should meet. Based on these observations, neonatal applications have been developed for an automated analysis of neonatal HRV in high frequencies only ( 0.15 Hz ) which is representative of parasympathetic activity. Technical developments have resulted in two specific devices (one ambulatory and one monitor) displaying a unique index: the Newborn Infant Parasympathetic Evaluation (NIPE). Several clinical studies have been carried out and they have shown that the NIPE index is able to evaluate prolonged pain, acute pain, discomfort, and comfortable stimulations. The NIPE index assesses the parasympathetic tone and could be a good decision support for medical staff. Long term studies are needed in order to evaluate the neuro-developmental benefits of continuously parasympathetic evaluation on neonates. |
Databáze: | OpenAIRE |
Externí odkaz: |