Trace determination of metal ion inhibitors of the urea-urease system by aph-stat kinetic method

Autor: E. Clifford Toren, F. Joseph Burger
Rok vydání: 1968
Předmět:
Zdroj: Microchimica Acta. 56:1049-1058
ISSN: 1436-5073
0026-3672
DOI: 10.1007/bf01221177
Popis: A pH-stat, kinetic method, based on the decreased rate of the ureasecatalyzed hydrolysis of urea, was developed for the trace determination of eight metal ion inhibitors. The kinetic parameters,vM andKm for the urease system and the apparent inhibition constants,K0′, for the metal ion interactions were measured. The sensitivities of the metal ions in decreasing order ofK0′ are: Ag(I) > Hg(II) > Cu(II) > Cd(II)> > Mn(II) ∼Co(II) > Pb(II) > Ni(II).
Databáze: OpenAIRE