Case study of sulfide generation and emission in sanitary sewer with drop structures and pump station
Autor: | Tong Yu, David Z. Zhu, Zhi Yang, Yanchen Liu, Stephen Edwini-Bonsu |
---|---|
Rok vydání: | 2019 |
Předmět: |
Canada
Environmental Engineering Sulfide 0208 environmental biotechnology Sewage 02 engineering and technology Sulfides 010501 environmental sciences Waste Disposal Fluid 01 natural sciences Water Pollutants Hydrogen Sulfide Sanitary sewer 0105 earth and related environmental sciences Water Science and Technology chemistry.chemical_classification business.industry Drop (liquid) Environmental engineering Trunk 6. Clean water 020801 environmental engineering chemistry Odorants Sulfide generation Environmental science business Retention time |
Zdroj: | Water Science and Technology. 79:1685-1694 |
ISSN: | 1996-9732 0273-1223 |
DOI: | 10.2166/wst.2019.164 |
Popis: | Field work was carried out to identify sewer odor hotspots and corresponding causes in a sanitary sewer trunk with drop structures and pump station in Steinhauer area, Edmonton, Canada. Relatively high concentrations of H2S were detected at the beginning and the end of the trunk with odor complaints. At the beginning of the trunk, sulfide emission was mainly caused by the increased stripping effect of the drop structures. The pump operation at the end of the trunk causes the long retention time of the sewage and the subsequent sulfide generation. The sulfide generation was modeled and calibrated using field measurements. The model was applied to assess mitigation strategies, and optimized pump operation was found to be able to reduce sulfide generation in the study trunk sewer. |
Databáze: | OpenAIRE |