Comparison of B-mode real-time ultrasound scanning with arteriography in detecting vascular defects during surgery
Autor: | Flanigan Dp, Schuler Jj, D G Spigos, J.C.U Coelho, J. Machi, B Sigel |
---|---|
Rok vydání: | 1982 |
Předmět: |
medicine.medical_specialty
Leg Intraoperative Care business.industry Angiography Real time ultrasound Reentry Surgery Blood Vessel Prosthesis Medicine Humans Radiology Nuclear Medicine and imaging Radiology Ultrasonography Lower extremity bypass business Intraoperative Complications Vascular Surgical Procedures |
Zdroj: | Radiology. 145(3) |
ISSN: | 0033-8419 |
Popis: | Real-time B-mode ultrasonography was compared with arteriography to determine its usefulness in detecting vascular defects immediately after lower extremity bypass graft reconstruction. Both procedures were employed in 40 patients to locate strictures, thrombi, and intimal flaps. Defects were discovered in 12 patients. Four of these defects were considered clinically insignificant and not worth the risk of reentry; of the remaining eight patients in whom significant defects were seen on ultrasonography, arteriography, or both, seven were reexplored. The accuracy of ultrasonography and arteriography was 94.4% and 83.3%, respectively. It is concluded that ultrasonography is comparable with arteriography in the detection of vascular defects during surgery. |
Databáze: | OpenAIRE |
Externí odkaz: |