Loading characteristics data applied on osseointegrated implant by transfemoral bone-anchored prostheses fitted with basic components during daily activities
Autor: | Laurent Frossard, Knut Lechler |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2019 |
Předmět: |
090302 Biomechanical Engineering
Activities of daily living Bone-anchored prosthesis (BAP) Computer science medicine.medical_treatment Prosthesis lcsh:Computer applications to medicine. Medical informatics Osseointegration 03 medical and health sciences 0302 clinical medicine Engineering Stairs Individual data medicine Amputation Artificial limb lcsh:Science (General) Prosthetic knees 030304 developmental biology Orthodontics 0303 health sciences Prosthetic feet Multidisciplinary Bone-anchored prosthesis Biomechanics anzsrc Australian and New Zealand Standard Research Class Loading Direct skeletal attachment Kinetics 090305 Rehabilitation Engineering Osseointegrated implants Prosthetic feet loading lcsh:R858-859.7 030217 neurology & neurosurgery lcsh:Q1-390 |
Zdroj: | Data in Brief, Vol 26, Iss, Pp-(2019) Data in Brief |
ISSN: | 2352-3409 |
Popis: | The data in this paper are related to the research articles entitled “Kinetics of transfemoral amputees with osseointegrated fixation performing common activities of daily living” (Lee et al., Clinical Biomechanics, 2007.22(6). p. 665–673) and “Magnitude and variability of loading on the osseointegrated implant of transfemoral amputees during walking” (Lee et al., Med Eng Phys, 2008.30(7). p. 825–833). This article contains the overall and individual loading characteristics applied on screw-type osseointegrated implant generated by transfemoral bone-anchored prostheses fitted with basic components during daily activities at self-selected comfortable pace. Overall and individual data was presented for the (A) spatio-temporal characteristics, (B) loading patterns, (C) loading boundaries and (D) the loading local extremum during level walking, ascending and descending ramp and stairs. Inter-participant variability of these new datasets with basic components is critical to improve the efficacy and safety of prosthetic components as well as the design of future automated algorithms and clinical trials. Online repository contains the files: https://data.mendeley.com/datasets/hh8rjjh73w/1. Keywords: Amputation, Artificial limb, Bone-anchored prosthesis (BAP), Direct skeletal attachment, Osseointegrated implants, Osseointegration, Prosthesis, Prosthetic knees, Prosthetic feet loading, Kinetics |
Databáze: | OpenAIRE |
Externí odkaz: |