A new dynamic six degrees of freedom disc-loading simulator allows to provoke disc damage and herniation
Autor: | Hans-Joachim Wilke, Annette Kienle, Sebastian Maile, Volker Rasche, Nikolaus Berger-Roscher |
---|---|
Rok vydání: | 2016 |
Předmět: |
Biomedical Research
0206 medical engineering 02 engineering and technology 03 medical and health sciences Imaging Three-Dimensional 0302 clinical medicine Lumbar Axial compression medicine Animals Six degrees of freedom Torque Orthopedics and Sports Medicine Intervertebral Disc Simulation Herniated discs Sheep business.industry Torsion (mechanics) Intervertebral disc 020601 biomedical engineering Biomechanical Phenomena Disease Models Animal medicine.anatomical_structure Intervertebral Disc Displacement Surgery business 030217 neurology & neurosurgery |
Zdroj: | European Spine Journal. 25:1363-1372 |
ISSN: | 1432-0932 0940-6719 |
DOI: | 10.1007/s00586-016-4416-5 |
Popis: | Purpose The cause of disc herniation is not well understood yet. It is assumed that heavy lifting and extreme postures can cause small injuries starting either in the inner anulus or from the outside close to the endplate. Such injuries are accumulated over years until its structure is weakened and finally a single loading event leads to a sudden failure of the last few intact lamellae. This paper describes a novel, custom-developed dynamic 6-DOF disc-loading simulator that allows complex loading to provoke such disc damage and herniations. Methods The machine’s axes are driven by six independent servomotors providing high loads (10 kN axial compression, 2 kN shear, 100 Nm torque) up to 5 Hz. A positional accuracy test was conducted to validate the machine. Subsequently, initial experiments with lumbar ovine motion segments under complex loading were performed. After testing, the discs were examined in an ultra-high field MRI (11.7 T). A three-dimensional reconstruction was performed to visualise the internal disc lesions. Results Validation tests demonstrated positioning with an accuracy of ≤0.08°/≤0.026 mm at 0.5 Hz and ≤0.27°/≤0.048 mm at 3.0 Hz with amplitudes of ±17°/±2 mm. Typical failure patterns and herniations could be provoked with complex asymmetrical loading protocols. Loading with axial compression, flexion, lateral bending and torsion lead in 8 specimens to 4 herniated discs, two protrusions and two delaminations. All disc failures occurred in the posterior region of the disc. Conclusion This new dynamic disc-loading simulator has proven to be able to apply complex motion combinations and allows to create artificial lesions in the disc with complex loading protocols. The aim of further tests is to better understand the mechanisms by which disc failure occurs at the microstructural level under different loading conditions. Visualisation with ultra-high field MRI at different time points is a promising method to investigate the gradual development of such lesions, which may finally lead to disc failure. These kinds of experiments will help to better investigate the mechanical failure of discs to provide new insights into the initiation of intervertebral disc herniation. This device will also serve for many other applications in spine biomechanics research. |
Databáze: | OpenAIRE |
Externí odkaz: |