Occupant Comfort and Indoor Temperature Reduction by Using Passive Air Conditioning System with Solar Chimney Concept in Hot Arid Climate

Autor: Amr Sayed Hassan Abdallah
Rok vydání: 2017
Předmět:
Zdroj: Amr Sayed Hassan Abdallah
ISSN: 1877-7058
Popis: Housing in Egypt consumes high energy for cooling. Bioclimatic building design is one of the strategies of sustainable development. The aim of the present research is to investigate the thermal performance of solar chimney with passive cooling wind tower (SCPC) on occupant’s comfort. The passive cooling design is integrated on the ceiling of 30 m 2 test house. Monitoring of indoor environment was carried out over a period of two months in the summer season (September and early October) with a 2 minute interval in order to calculate thermal comfort sensation, Predicted mean vote (PMV) and PPD. The results show that outlet air temperature from the wind tower is 27.3°C. The calculated predicted mean vote (PMV) is within the recommended range (-0.5