Challenging the six-hour recommendation for reprocessing sterilizable medical equipment
Autor: | Ann-Eva Christensen, Ripadal K, Henrik Carl Schønheyder, Bundgaard K, Erik Elgaard Sørensen |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2019 |
Předmět: |
Microbiology (medical)
Time Factors Protein residue Denmark Medical equipment Dentistry Sterilization/methods O-Phthalaldehyde Pitting corrosion Medicine Humans Holding time Decontamination Proteins/analysis Microscopy Human blood business.industry Surgical instruments Proteins Sterilization General Medicine Surgical Instruments Corrosion Reprocessing Infectious Diseases Decontamination/methods Surgical scissors Equipment Contamination Microscopy Electron Scanning Indicators and Reagents business o-Phthalaldehyde |
Zdroj: | Bundgaard, K, Sorensen, E E, Ripadal, K, Christensen, A-E & Schønheyder, H C 2019, ' Challenging the six-hour recommendation for reprocessing sterilizable medical equipment ', Journal of Hospital Infection, vol. 101, no. 1, pp. 13-19 . https://doi.org/10.1016/j.jhin.2018.10.009 |
Popis: | Summary Background At present, reprocessing of sterilizable medical equipment is recommended to be initiated within 6 h after completion of surgery, to ensure that the quality of the instruments does not deteriorate. A literature search showed a lack of evidence for consequences that may occur if medical personnel deviate from the standard 6 h sterilization protocol. Aim To evaluate the 6 h recommendation for reprocessing sterilizable medical equipment by determining whether residual protein increased proportional to holding time before reprocessing was initiated, and likewise whether an increase in corrosion was present on surgical scissors proportional to holding time. Methods Residual protein was identified on surgical instruments contaminated with human blood after different holding times and before washes using the o-phthaldialdehyde (OPA) method. Corrosion was identified on surgical scissors contaminated with human blood after different holding times and after reprocessing using light stereomicroscopy and scanning electron microscopy. Findings Protein residues ranged between 14.0 and 51.9 μg and thus below the accepted threshold of 100 μg per instrument surface. Corrosion corresponding to 0.05% of the surface was identified on 22 of 30 scissors. Pitting corrosion was seen on four of 30 scissors. Conclusion No association was identified between residual protein and holding time, nor between incidence of corrosion and holding time. The study thereby challenges the relevance of upholding the recommendation of a maximum wait of 6 h prior to reprocessing. The findings will potentially have an impact on the organization of reprocessing of surgical instruments in Denmark and internationally. |
Databáze: | OpenAIRE |
Externí odkaz: |