Comparison of routinely used intestinal biopsy forceps in dogs: an ex vivo histopathological approach

Autor: D. Concordet, Olivier Dossin, Isabelle Raymond-Letron, M. O. Semin, S. Amiriantz, C. Monton, Julien M. Dahan
Přispěvatelé: Department of Clinical Sciences and Clinical Research Unit, Ecole Nationale Vétérinaire de Toulouse (ENVT), Institut National Polytechnique (Toulouse) (Toulouse INP), Université Fédérale Toulouse Midi-Pyrénées-Université Fédérale Toulouse Midi-Pyrénées-Institut National Polytechnique (Toulouse) (Toulouse INP), Université Fédérale Toulouse Midi-Pyrénées-Université Fédérale Toulouse Midi-Pyrénées, Department of Biological Sciences, The Open University [Milton Keynes] (OU), Institut de Recherche en Santé Digestive (IRSD ), Institut National de la Recherche Agronomique (INRA)-Université Toulouse III - Paul Sabatier (UT3), Université Fédérale Toulouse Midi-Pyrénées-Université Fédérale Toulouse Midi-Pyrénées-Ecole Nationale Vétérinaire de Toulouse (ENVT), Université Fédérale Toulouse Midi-Pyrénées-Institut National de la Santé et de la Recherche Médicale (INSERM), Université Toulouse III - Paul Sabatier (UT3), Université Fédérale Toulouse Midi-Pyrénées-Université Fédérale Toulouse Midi-Pyrénées-Institut National de la Recherche Agronomique (INRA)-Ecole Nationale Vétérinaire de Toulouse (ENVT)
Jazyk: angličtina
Rok vydání: 2017
Předmět:
Zdroj: Journal of Small Animal Practice
Journal of Small Animal Practice, Wiley, 2017, 58 (3), pp.162-167. ⟨10.1111/jsap.12643⟩
ISSN: 0022-4510
1748-5827
DOI: 10.1111/jsap.12643⟩
Popis: OBJECTIVES To compare the quality of duodenal and ileal samples obtained with different biopsy forceps. METHODS Fifteen dogs were included in a prospective ex vivo study. After euthanasia, the duodenum and the ileum were sampled with four different forceps and evaluated according to a standardised scoring system. The biopsy forceps evaluated had alligator jaws or cups with smooth edge with or without a needle. RESULTS The global quality of the biopsies was better in the ileum that in the duodenum regardless of the biopsy forceps. Biopsy forceps with smooth edge including a needle resulted in fewer artefacts than biopsy forceps with smooth edge but no needle in both sites and those with alligator jaws without a needle provided deeper biopsies than those with smooth edge without a needle only in the duodenum. There was no effect of the biopsy forceps type on the size of the biopsies. CLINICAL SIGNIFICANCE Our findings may aid in choosing the appropriate type of forceps for intestinal biopsy.
Databáze: OpenAIRE