Comparison of line-by-line and molecular band IR modeling of high altitude missile plume
Autor: | Kurt Beier, Erwin Lindermeir |
---|---|
Rok vydání: | 2007 |
Předmět: |
high spectral resolution
Physics Radiation business.industry Infrared Ballistic missile Atomic and Molecular Physics and Optics Plume Optics Missile line-by-line calculation Keywords: Infrared modeling Astrophysics::Earth and Planetary Astrophysics HITRAN Spectral resolution business IR signature high altitude missile plume FASCODE 3 HITEMP comparison of model calculations Spectroscopy Line (formation) |
Zdroj: | Journal of Quantitative Spectroscopy and Radiative Transfer. 105:111-127 |
ISSN: | 0022-4073 |
DOI: | 10.1016/j.jqsrt.2006.09.019 |
Popis: | This paper deals with the quantitative comparison of modeling IR radiation emitted from the plume of a tactical ballistic missile (TBM) in the boost phase with two different model approaches. IR spectra of the missile plume are calculated both with the high spectral resolution line-by-line radiation model FASCODE 3 (fast atmospheric signature code) using the databases HITEMP or HITRAN and the low spectral resolution IR radiation model NIRATAM (NATO InfraRed Air TArget Model) using molecular band model technique. The influence of the atmosphere on the IR spectra as viewed from a space born sensor is taken into account. The results show, that using an elaborate line-by-line radiation model can improve the accuracy in computation of IR signature compared to the simpler but faster molecular band model technique used in NIRATAM. |
Databáze: | OpenAIRE |