Three Approaches to the Radioimmunoassay of Human β-Thromboglobulin
Autor: | C.A. Ludlam, S. Moore, A.E. Bolton, J. D. Cash, D. S. Pepper |
---|---|
Rok vydání: | 1976 |
Předmět: | |
Zdroj: | British Journal of Haematology. 33:233-238 |
ISSN: | 1365-2141 0007-1048 |
DOI: | 10.1111/j.1365-2141.1976.tb03534.x |
Popis: | Three radioimmunoassays for the measurement of beta-thromboglobulin are described. The standard method, using antiserum in solution, could be used to measure plasma concentrations of beta-thromboglobulin with the results available after 2-3 d. The use of a greater dilution of antiserum and tracer, with delayed addition of tracer, resulted in a more sensitive assay suitable for measuring b-thromboglobulin in urine. The use of a solid-couples antiserum under non-equilibrium conditions allowed the measurement of plasma levels of beta-thromboglobulin after an assay incubation time of 1 h. These three radioimmunoassay systems for beta-thromboglobulin cover the likely clinical requirements for the measurement of this platelet specific protein. |