Two-harmonic Periodic Disturbance Compensation for Dead-Time Processes with Online Identification of Input Delay
Autor: | Adam Peichl, Michal Kuchař, Can Kutlu Yuksel, Silviu-Iulian Niculescu, Tomáš Vyhlídal |
---|---|
Přispěvatelé: | Faculty of Mechanical Engineering [Prague] (CTU/FME), Czech Technical University in Prague (CTU), Laboratoire des signaux et systèmes (L2S), CentraleSupélec-Université Paris-Saclay-Centre National de la Recherche Scientifique (CNRS), Dynamical Interconnected Systems in COmplex Environments (DISCO), Inria Saclay - Ile de France, Institut National de Recherche en Informatique et en Automatique (Inria)-Institut National de Recherche en Informatique et en Automatique (Inria)-Laboratoire des signaux et systèmes (L2S), CentraleSupélec-Université Paris-Saclay-Centre National de la Recherche Scientifique (CNRS)-CentraleSupélec-Université Paris-Saclay-Centre National de la Recherche Scientifique (CNRS), Czech Science Foundation project No.21-07321S, Grant Agency of the Czech Technical University in Prague, student grants No. SGS21/152/OHK2/3T/12 and SGS20/159/OHK2/3T/12, Public grant overseen by the French National research Agency(ANR) as part of the Investissements d’Avenir program, through the 'ADI2020' project funded by the IDEX Paris-Saclay, ANR-11-IDEX-0003-02, ANR-11-IDEX-0003,IPS,Idex Paris-Saclay(2011) |
Rok vydání: | 2022 |
Předmět: | |
Zdroj: | TDS 2022-17th IFAC Workshop on Time Delay Systems TDS 2022-17th IFAC Workshop on Time Delay Systems, Sep 2022, Montréal, Canada |
ISSN: | 2405-8963 |
DOI: | 10.1016/j.ifacol.2022.11.336 |
Popis: | International audience; As in the case of the Smith predictor, when applied to dynamical systems with delay in the input, the stability of the internal model control (IMC) system can be very sensitive to the mismatch that can occur between the plant delay and the identified delay. In this paper, we propose an online identification technique for the plant with input delay, which is used to adapt an IMC controller designed to reject periodic disturbances consisting of two harmonics. The proposed method is based on wavelet analysis and cross-correlation of the measured output. Moreover, the proposed controller structure introduces a novel analytical approach which makes it suitable for the adaptive application. The practical motivation of the study is to address the delay mismatch that can be caused by approximating time-varying high-order systems by first-order models with input delay. The approach is numerically validated. |
Databáze: | OpenAIRE |