Accuracy of different modalities of reaction time testing: Implications for online cognitive assessment tools

Autor: Francisco E, Laila Zai, Rachel Lensch, Mark Tommerdahl, Kirsch B, Robert G. Dennis, Holden J, Tommerdahl A
Jazyk: angličtina
Rok vydání: 2019
Předmět:
DOI: 10.1101/726364
Popis: Reaction time testing is widely used in computerized cognitive assessments, and clinical studies have repeatedly shown it to be a sensitive indicator of cognitive function. Typically, the reaction time test is administered by presenting a subject with a visual stimulus on a computer monitor and prompting the individual to respond (via keypad or computer mouse) as quickly as possible. The individual’s reaction time is calculated as the interval between presentation of the stimulus and the time recorded from the mechanical response. However, there are many inherent latencies and variabilities that may be introduced to the measure by both hardware (computer monitor and mouse) and software (operating system). Because of these delays, we hypothesized that a comparison of hardware protocols (excluding human response) would demonstrate significant differences in the resulting reaction time measures. To simulate the delays of various components of the common systems used to obtain reaction time, we conducted a simple experiment in which either a visual or tactile stimulus evoked a movement from a mechanical transducer to respond to a computer peripheral or a dedicated response device. In the first condition, a simulated visual reaction time test was conducted by flashing a visual stimulus on a computer monitor. The stimulus was detected by a dedicated light sensor, and a linear actuator delivered the mechanical response via computer mouse. The second test condition employed a mobile device as the medium for the visual stimulus, and the mechanical response was delivered to the mobile device’s touchscreen. The third and fourth test conditions simulated tactile reaction time tests in which the stimulus was generated by a dedicated hardware device. The third condition simulated a tactile stimulus, which was detected by a mechanical switch, and again a hardware device delivered the response via computer mouse. The fourth condition also simulated a tactile stimulus, but the response was delivered by a dedicated hardware device designed to store the interval between stimulus delivery and stimulus response. There were significant differences in the range of responses recorded from the four different conditions with the reaction time collected from a visual stimulus on a mobile device being the worst and the device with dedicated hardware designed for the task being the best. The results suggest that some of the commonly used visual tasks on consumer grade computers could be introducing significant errors for reaction time testing and that dedicated hardware designed for the reaction time task is needed to minimize testing errors.
Databáze: OpenAIRE