Pacemaker therapy in low-birth-weight infants

Autor: Atsuya Shimabukuro, Nobuhiro Nagata, Masahiko Nishioka, Toru Akashige, Tai Fuchigami
Rok vydání: 2018
Předmět:
Zdroj: Journal of Cardiac Surgery. 33:118-121
ISSN: 0886-0440
DOI: 10.1111/jocs.13529
Popis: Infants born with complete atrioventricular block (CAVB) and fetal bradycardia are frequently born with low birth weight. Three low-birth-weight CAVB infants underwent temporary pacemaker implantation, followed by permanent single-chamber pacemaker implantation at median body weights of 1.7 and 3.2 kg, respectively. All infants caught up with their growth curves and had >3 years of estimated residual battery life. This two-stage strategy was successful in facilitating permanent pacemaker implantation in low-birth-weight babies. Placement of single-chamber pacemaker on the apex of the left ventricle appears to be associated with longer battery lifespan.
Databáze: OpenAIRE