medicine.medical_specialty medicine.medical_treatment Fusiform Aneurysm Kidney Prosthesis Design Aortic stent Aortic aneurysm Aneurysm Stent medicine Humans Endovascular treatment cardiovascular diseases Aged Medicine(all) Unusual case Self expandable business.industry Endovascular Procedures medicine.disease Abdominal aortic aneurysm Surgery cardiovascular system Stents Radiology Cardiology and Cardiovascular Medicine business Aortic Aneurysm Abdominal |
Zdroj: | European Journal of Vascular and Endovascular Surgery. 45:465-467 |
ISSN: | 1078-5884 |
DOI: | 10.1016/j.ejvs.2013.01.040 |
Popis: | Introduction We report a case of an emergency high-risk patient with a pararenal aortic aneurysm. Report Our patient had a pararenal aneurysm with two components: a wide-neck saccular aneurysm below the left renal artery and a fusiform aneurysm. A self-expandable aortic stent was deployed covering both renal arteries, the saccular aneurysm was embolised with microcoils and a bifurcated aortic endograft was anchored inside the aortic stent. The aortic stent imprisoned the microcoils and avoided proximal type I endoleak. The tomography done 15 months after the procedure showed no endoleaks. Discussion A self-expandable aortic stent can provide an alternative for emergency high-risk patients with pararenal aortic aneurysms. |