'Chopper Shield' Technique to Protect Corneal Endothelium During Phacoemulsification Surgery for Rock Hard Cataracts
Autor: | Rasik B Vajpayee, Tushya Om Parkash, Rohit Om Parkash, Shruti Mahajan |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2021 |
Předmět: |
medicine.medical_specialty
Corneal endothelium genetic structures medicine.medical_treatment Chopper 03 medical and health sciences corneal endothelium 0302 clinical medicine Corneal edema Cataracts Ophthalmology medicine Prospective cohort study Original Research business.industry chopper shield Clinical Ophthalmology Phacoemulsification medicine.disease eye diseases Surgery Endothelial cell density Endothelial stem cell cataract phacoemulsification 030221 ophthalmology & optometry sense organs hard cataract business 030217 neurology & neurosurgery |
Zdroj: | Clinical Ophthalmology (Auckland, N.Z.) |
ISSN: | 1177-5483 1177-5467 |
Popis: | Tushya Om Parkash,1 Rohit Om Parkash,1 Shruti Mahajan,1 Rasik Vajpayee2– 4 1Cataract Department, Dr Om Parkash Eye Institute, Amritsar, Punjab, India; 2Eye Department, Vision Eye Institute, Melbourne, Victoria, Australia; 3Eye Department, Royal Victorian Eye and Ear Hospital, Melbourne, Victoria, Australia; 4Department of Surgery, University of Melbourne, Melbourne, Victoria, AustraliaCorrespondence: Shruti MahajanDr Om Parkash Eye Institute, 117-A, The Mall, Amritsar, Punjab, 143001, IndiaTel +91-9872553424Email shrutim84@gmail.comPurpose: To describe an innovative technique of using a chopper as a shield for preventing mechanical corneal endothelial trauma that can occur during the phacoemulsification of brunescent cataracts.Methods: This prospective study included patients with hard cataracts (grade nuclear opalescence 4 and above on LOCS III) who underwent phacoemulsification surgery. The chopper shield technique was performed in 48 eyes of 44 patients. The technique entailed placing the chopper horizontally as a shield anterior to the emulsifying nuclear fragment between the phaco tip and corneal endothelium to prevent nucleus fragments from coming into contact with the corneal endothelium. Outcome measures included cumulative dissipated energy (CDE), corneal edema (day one), CCT (assessed at one day, one week, and one month), and endothelial cell density assessed at three months.Results: Of the 48 eyes included in the study, 23 were males and 25 were females (mean age: 70.02± 5.98years). Preoperatively, mean central corneal thickness (CCT) was 529.62± 21.70 microns, and endothelial cell counts were 2258.76± 182.22 cells per mm2. Postoperatively on day one, CCT increased to 563.93± 24.53 microns, a 6.47% increase from preoperative central corneal thickness. CCT became 534.83± 22.64 microns on postoperative day seven, a 0.98% increase from preoperative CCT. Endothelial cell loss was 6.77% at three months from the day of surgery.Conclusion: The chopper shield technique offers continuous protection to the corneal endothelium by minimizing endothelial cell loss during phacoemulsification of dense nuclear cataracts.Keywords: cataract, phacoemulsification, hard cataract, corneal endothelium, chopper shield |
Databáze: | OpenAIRE |
Externí odkaz: | |
Nepřihlášeným uživatelům se plný text nezobrazuje | K zobrazení výsledku je třeba se přihlásit. |