Reliability and Failure Modes of Implant-Supported Y-TZP and MCR Three-Unit Bridges
Autor: | Nelson R.F.A. Silva, Gérson Bonfante, Jose Manuel Navarro Jr., Van P. Thompson, Estevam A. Bonfante, Paulo G. Coelho, Luiz Fernando Pegoraro |
---|---|
Rok vydání: | 2009 |
Předmět: |
Dental Implants
Dental Stress Analysis Materials science Dental prosthesis Abutment Reproducibility of Results Dental Abutments Dental Porcelain Cracking Dental porcelain PRÓTESE PARCIAL FIXA Flexural strength Denture Partial Fixed Humans Ultimate failure Dental Prosthesis Implant-Supported Dental Restoration Failure Zirconium Oral Surgery Composite material General Dentistry Reliability (statistics) Implant supported Dental Alloys |
Zdroj: | Repositório Institucional da USP (Biblioteca Digital da Produção Intelectual) Universidade de São Paulo (USP) instacron:USP |
ISSN: | 1708-8208 1523-0899 |
Popis: | Purpose: Chipping within veneering porcelain has resulted in high clinical failure rates for implant-supported zirconia (yttria-tetragonal zirconia polycrystals [Y-TZP]) bridges. This study evaluated the reliability and failure modes of mouth-motion step-stress fatigued implant-supported Y-TZP versus palladium-silver alloy (PdAg) three-unit bridges. Materials and Methods: Implant-abutment replicas were embedded in polymethylmethacrylate resin. Y-TZP and PdAg frameworks, of similar design (n = 21 each), were fabricated, veneered, cemented (n = 3 each), and Hertzian contact-tested to obtain ultimate failure load. In each framework group, 18 specimens were distributed across three step-stress profiles and mouth-motion cyclically loaded according to the profile on the lingual slope of the buccal cusp of the pontic. Results: PdAg failures included competing flexural cracking at abutment and/or connector area and chipping, whereas Y-TZP presented predominantly cohesive failure within veneering porcelain. Including all failure modes, the reliability (two-sided at 90% confidence intervals) for a “mission” of 50,000 and 100,000 cycles at 300 N load was determined (Alta Pro, Reliasoft, Tucson, AZ, USA). No difference in reliability was observed between groups for a mission of 50,000. Reliability remained unchanged for a mission of 100,000 for PdAg, but significantly decreased for Y-TZP. Conclusions: Higher reliability was found for PdAg for a mission of 100,000 cycles at 300 N. Failure modes differed between materials. |
Databáze: | OpenAIRE |
Externí odkaz: |