Modified Schirmer tear test and rebound tonometry in blue-fronted Amazon parrot (Amazona aestiva)

Autor: Rafael Veríssimo Monteiro, Paula Diniz Galera, Arianne Pontes Oriá, Mário Sérgio Almeida Falcão
Jazyk: angličtina
Předmět:
pressão intraocular
medicine.medical_specialty
Intraocular pressure
040301 veterinary sciences
Amazon parrot
Tonometria
produção lacrimal
0403 veterinary science
03 medical and health sciences
papagaio-verdadeiro
0302 clinical medicine
aves
Ophthalmology
wild animals
medicine
biology.domesticated_animal
lacrimal production
Blue-fronted amazon
Aparelho lacrimal
tonometry
lcsh:Veterinary medicine
General Veterinary
biology
Ave
business.industry
comprimento da fissura palpebral
Pressão intra-ocular
04 agricultural and veterinary sciences
REBOUND TONOMETRY
Schirmer tear test
biology.organism_classification
Amazona aestiva
eye diseases
Palpebral fissure
Papagaio (Ave)
animais silvestres
palpebral fissure length
Teste lacrimal de Schirmer modificado
Reference values
birds
030221 ophthalmology & optometry
lcsh:SF600-1100
business
tonometria de rebote
intraocular pressure
Zdroj: Pesquisa Veterinária Brasileira, Vol 37, Iss 8, Pp 871-873
Pesquisa Veterinária Brasileira, Volume: 37, Issue: 8, Pages: 871-873, Published: AUG 2017
Repositório Institucional da UnB
Universidade de Brasília (UnB)
instacron:UNB
Pesquisa Veterinária Brasileira v.37 n.8 2017
Pesquisa Veterinária Brasileira
Colégio Brasileiro de Patologia Animal (CBPA)
instacron:EMBRAPA
ISSN: 1678-5150
Popis: The aim of this study was to describe the modified Schirmer tear test (mSTT), intraocular pressure (IOP) by rebound tonometry and palpebral fissure length (PFL) in blue-fronted Amazon parrots (Amazona aestiva). Thirty-five healthy adult animals from a conservation breeding center in Brazil were used in this study. Modified Schirmer tear test, rebound tonometry and PFL measurements were performed in both eyes, with birds under physical restraint. Mean mSTT was 6.2±0.1mm/min and mean IOP was 6.4±0.1mmHg, while PFL was 10.1±0.1mm. A moderate correlation was seen between mSTT and PFL for OD (ρ=0.14) and OS (ρ=0.20). The results provide ophthalmic tests reference values for A. aestiva. RESUMO: O objetivo deste estudo foi descrever o teste lacrimal de Schirmer modificado (TLSm), a pressão intraocular (PIO) pela tonometria de rebote e o comprimento da fissura palpebral (FP) do papagaio-verdadeiro (Amazona aestiva). Foram avaliados 35 papagaios adultos e saudáveis, provenientes de um Criadouro Conservacionista do Brasil. Após avaliação clínica e laboratorial, as aves foram fisicamente contidas para aferição, em ambos os olhos, do TLSm, da PIO pela tonometria de rebote e do comprimento da FP utilizando-se um paquímetro digital. Valor médio do TLSm foi 6.2±0.1mm/min e da PIO foi 6.4±0.1 mmHg, enquanto a aferição da FP foi 10.1±0.1mm. Uma correlação moderada foi observada entre TLSm e a FP para olho direito (OD) (ρ=0.14) e olho esquerdo (OE) (ρ=0.20). Os resultados podem servir como valores de referência para testes oftálmicos para A. aestiva.