A compact multichannel spectrometer for label-free monitoring of biochips for point-of-care testing

Autor: Sylvain Deprez, Edurne Tellechea, Maxime Denti, Hendrik Von Horsten, Juriy Hastanin, S. Maricot, Miguel Holgado, Aline Roobroek, Fabian Dortu, María V. Maigler, Fátima Fernández, Iñaki Cornago, Damien Bernier, Theo Veenstra, Yves Hernandez, Rafael Casquel, Cedric Lenaerts, Ana L. Hernandez, Jean-Pierre Vilcot, Paula Ciaurriz
Přispěvatelé: Institut d'électronique fondamentale (IEF), Université Paris-Sud - Paris 11 (UP11)-Centre National de la Recherche Scientifique (CNRS), Química Analítica, Nutrición y Bromatología, University of Santiago de Compostela, Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 (IEMN), Centrale Lille-Institut supérieur de l'électronique et du numérique (ISEN)-Université de Valenciennes et du Hainaut-Cambrésis (UVHC)-Université de Lille-Centre National de la Recherche Scientifique (CNRS)-Université Polytechnique Hauts-de-France (UPHF), Optoélectronique - IEMN (OPTO - IEMN), Centrale Lille-Institut supérieur de l'électronique et du numérique (ISEN)-Université de Valenciennes et du Hainaut-Cambrésis (UVHC)-Université de Lille-Centre National de la Recherche Scientifique (CNRS)-Université Polytechnique Hauts-de-France (UPHF)-Centrale Lille-Institut supérieur de l'électronique et du numérique (ISEN)-Université de Valenciennes et du Hainaut-Cambrésis (UVHC)-Université de Lille-Centre National de la Recherche Scientifique (CNRS)-Université Polytechnique Hauts-de-France (UPHF), Universidade de Santiago de Compostela [Spain] (USC )
Jazyk: angličtina
Rok vydání: 2019
Předmět:
Zdroj: SPIE Proceedings Volume 11073, Clinical and Preclinical Optical Diagnostics II; 1107314
European Conferences on Biomedical Optics, 2019
European Conferences on Biomedical Optics, 2019, Jun 2019, Munich, Germany. pp.39, ⟨10.1117/12.2526953⟩
Popis: We present three optical multi-channels spectrometers for the interrogation of label-free biosensors based on different kinds of transducers: resonant nanopillars (RNP), microring resonators (MRR), localized and propagative surface plasmon resonance (LSPR and SPR). Light is collected from the multi-channel biosensors (up to 12-channels) with optical fibers and is remapped to a packed straight line forming the input slit of the spectrometers. The combination of high resolution CMOS sensors and embedded signal processing makes it possible to extract the resonant wavelengths of the transducers with a precision in the range of 1-20 pm depending on the type of transducer.The performance of the three transducer / spectrometer systems has been evaluated in the framework of EU and regional projects for the monitoring of chemical pollutants found in oceanic waters (FP7 - EnviGuard), crop health monitoring (Interreg France-Wallonie-Vlaanderen - SmartBioControl/BioSens) and bioreactor monitoring (EutoTransBio -APTACHIP).
Databáze: OpenAIRE