Dropped head syndrome after cervical laminoplasty: A case control study

Autor: Kazuhisa Takahashi, Mitsutoshi Ota, Junya Saito, Takeo Furuya, Masashi Yamazaki, Satoshi Maki, Chikato Mannoji, Yasushi Ijima, Tomohiro Miyashita, Masaaki Aramomi, Tomoaki Kinoshita, Masao Koda
Rok vydání: 2016
Předmět:
Zdroj: Journal of Clinical Neuroscience. 32:88-90
ISSN: 0967-5868
DOI: 10.1016/j.jocn.2016.03.027
Popis: Dropped head syndrome (DHS) is characterized by apparent neck extensor muscle weakness and difficulty extending the neck to raise the head against gravity. The aim of the present study was to elucidate possible risk factors for DHS after cervical laminoplasty. Five patients who developed DHS after cervical laminoplasty (DHS group) and twenty age-matched patients who underwent laminoplasty without DHS after surgery (control group) were compared. The surgical procedure was single-door laminoplasty with strut grafting using resected spinous processes or hydroxyapatite spacers from C3 to C6 or C7. Analyses of preoperative images including the C2-C7 angle, C7-T1 kyphosis, T1 tilt, center of gravity line from the head-C7 sagittal vertical axis (CGH-C7 SVA) were performed on lateral plain cervical spine radiographs. Preoperative T2-weighted MRI at the C5 vertebral level was used to measure the cross-sectional area of the deep extensor muscles. Widths of the lateral gutters were assessed postoperatively using CT scans of the C5 vertebral body. The average preoperative C2-C7 angle was significantly smaller in the DHS group compared with the control group. The average preoperative C7-T1 angle was significantly larger in the DHS group compared with the control group. The average preoperative CGH-C7 SVA was significantly larger in the DHS group compared with the control group. In conclusion, patients with more pronounced preoperative C2-C7 kyphosis, C7-T1 kyphosis, and CGH-C7 SVA are more likely to develop DHS following laminoplasty.
Databáze: OpenAIRE