Optimization of magnetic resonance imaging protocol for the diagnosis of transient global amnesia
Autor: | André Evangelista Torres, Luiz de Abreu Junior, Ulysses dos Santos Torres, Luciana Pinheiro dos Santos Vaz, Laiz Laura de Godoy, Angela Maria Borri Wolosker, Maria Lucia Borri |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2019 |
Předmět: |
lcsh:Medical physics. Medical radiology. Nuclear medicine
Diffusion magnetic resonance imaging lcsh:R895-920 Slice thickness Amnesia Hippocampus 03 medical and health sciences 0302 clinical medicine Magnetic resonance imaging Right hippocampus Memory medicine Brain mri Hipocampo Memória Radiology Nuclear Medicine and imaging 030212 general & internal medicine Symptom onset Time point Amnésia global transitória medicine.diagnostic_test Amnesia transient global business.industry Original Articles medicine.disease Ressonância magnética Transient global amnesia Difusão Amnésia medicine.symptom Nuclear medicine business 030217 neurology & neurosurgery |
Zdroj: | Radiologia Brasileira Radiologia Brasileira, Issue: ahead, Published: 09 MAY 2019 Radiologia Brasileira, Volume: 52, Issue: 3, Pages: 161-165, Published: 09 MAY 2019 Radiologia Brasileira, Iss 0 (2019) Radiologia Brasileira v.52 n.3 2019 Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR) instacron:CBR |
ISSN: | 1678-7099 0100-3984 |
Popis: | Objective: To emphasize the most appropriate magnetic resonance imaging (MRI) diffusion protocol for the detection of lesions that cause transient global amnesia, in order to perform an accurate examination, as well as to determine the ideal time point after the onset of symptoms to perform the examination. Materials and Methods: We evaluated five patients with a diagnosis of transient global amnesia treated between 2012 and 2015. We analyzed demographic characteristics, clinical data, symptom onset, diffusion techniques, and radiological findings. Examination techniques included a standard diffusion sequence (b value = 1000 s/mm2; slice thickness = 5 mm) and a optimized diffusion sequence (b value = 2000 s/mm2; slice thickness = 3 mm). Results: Brain MRI was performed at 24 h or 36 h after symptom onset, except in one patient, in whom it was performed at 12 h after (at which point no changes were seen) and repeated at 36 h after symptom onset (at which point it showed alterations in the right hippocampus). The standard and optimized diffusion sequences were both able to demonstrate focal changes in the hippocampi in all of the patients but one, in whom the changes were demonstrated only in the optimized sequence. Conclusion: MRI can confirm a clinical hypothesis of transient global amnesia. Knowledge of the optimal diffusion parameters and the ideal timing of diffusion-weighted imaging (> 24 h after symptom onset) are essential to improving diagnostic efficiency. Resumo Objetivo: Enfatizar o protocolo de difusão mais adequado para detecção de lesões da amnésia global transitória, a fim de realizar um exame preciso, em tempo ideal, após o início dos sintomas. Materiais e Métodos: Foram analisados cinco pacientes com diagnóstico de amnésia global transitória atendidos entre 2012 e 2015, considerando-se dados demográficos, clínicos, tempo do início dos sintomas, técnicas de difusão e achados radiológicos. As técnicas incluíram uma sequência de difusão padrão (b = 1000 s/mm2; espessura do corte = 5 mm) e uma sequência de difusão otimizada (b = 2000 s/mm2; espessura de corte = 3 mm). Resultados: A ressonância magnética de encéfalo foi realizada após 24 ou 36 horas do início dos sintomas, exceto em um paciente, em que foi realizada após 12 horas (sem alterações) e repetida após 36 horas (mostrando alterações hipocampais). Em todos os pacientes foram demonstradas alterações focais na difusão no hipocampo em ambas as técnicas, exceto em um paciente, em que as alterações foram demonstradas apenas na sequência otimizada. Conclusão: A ressonância magnética é capaz de confirmar a hipótese clínica de amnésia global transitória. O conhecimento dos parâmetros ótimos da técnica de difusão e o melhor tempo para a detecção das alterações (> 24 horas) são essenciais para aprimorar a eficiência diagnóstica. |
Databáze: | OpenAIRE |
Externí odkaz: |