Evaluation of recycled tiles and OSB ceiling materials in closed broiler house prototypes

Autor: R. da Fonseca, V. C. da Cruz, Francisco Antonio Rocco Lahr, Juliano Fiorelli, J. C. M. Cravo
Přispěvatelé: Universidade Estadual Paulista (Unesp), Universidade de São Paulo (USP)
Předmět:
Zdroj: Scopus-Elsevier
Brazilian Journal of Poultry Science v.11 n.4 2009
Brazilian Journal of Poultry Science
Fundação APINCO de Ciência e Tecnologia Avícolas (FACTA)
instacron:FACTA
Revista Brasileira de Ciência Avícola, Volume: 11, Issue: 4, Pages: 219-224, Published: DEC 2009
SciELO
Repositório Institucional da UNESP
Universidade Estadual Paulista (UNESP)
instacron:UNESP
Brazilian Journal of Poultry Science, Vol 11, Iss 4, Pp 219-224 (2009)
ResearcherID
ISSN: 1516-635X
Popis: Submitted by Guilherme Lemeszenski (guilherme@nead.unesp.br) on 2013-08-22T18:40:16Z No. of bitstreams: 1 S1516-635X2009000400002.pdf: 1179462 bytes, checksum: ebeaf2b4096ee2d132a923fddf65a067 (MD5) Made available in DSpace on 2013-08-22T18:40:16Z (GMT). No. of bitstreams: 1 S1516-635X2009000400002.pdf: 1179462 bytes, checksum: ebeaf2b4096ee2d132a923fddf65a067 (MD5) Previous issue date: 2009-12-01 Made available in DSpace on 2013-09-30T19:25:36Z (GMT). No. of bitstreams: 2 S1516-635X2009000400002.pdf: 1179462 bytes, checksum: ebeaf2b4096ee2d132a923fddf65a067 (MD5) S1516-635X2009000400002.pdf.txt: 22033 bytes, checksum: 7d8e0ce59a5cc80dfedb1d39bd174019 (MD5) Previous issue date: 2009-12-01 Submitted by Vitor Silverio Rodrigues (vitorsrodrigues@reitoria.unesp.br) on 2014-05-20T15:07:15Z No. of bitstreams: 2 S1516-635X2009000400002.pdf: 1179462 bytes, checksum: ebeaf2b4096ee2d132a923fddf65a067 (MD5) S1516-635X2009000400002.pdf.txt: 22033 bytes, checksum: 7d8e0ce59a5cc80dfedb1d39bd174019 (MD5) Made available in DSpace on 2014-05-20T15:07:15Z (GMT). No. of bitstreams: 2 S1516-635X2009000400002.pdf: 1179462 bytes, checksum: ebeaf2b4096ee2d132a923fddf65a067 (MD5) S1516-635X2009000400002.pdf.txt: 22033 bytes, checksum: 7d8e0ce59a5cc80dfedb1d39bd174019 (MD5) Previous issue date: 2009-12-01 This study aimed at evaluating the thermal performance of a modular ceiling system for poultry houses. The reduced- and distorted-scale prototypes used ceiling modules made of reforested wood and were covered with recycled long-life package tiles. The following parameters were measured for 21 days: tile internal surface temperature (ST), globe temperature and humidity index (WBGT), and radiant heat load (RHL). Measurements were made at times of highest heat load (11:00 am, 13:00 pm, and 03:00 pm). Collected data were analyzed by R statistics software. Means were compared by multiple comparison test (Tukey) and linear regression was performed, both at 5% significance level. The results showed that the prototype with the ceiling was more efficient to reduce internal tile surface temperature; however, this was not sufficient to provide a comfortable environment for broilers during the growout. Therefore, other techniques to provide proper cooling are required in addition to the ceiling. Universidade Estadual Paulista Júlio de Mesquita Filho Universidade de São Paulo Faculdade de Zootecnia e Engenharia de Alimento Universidade de São Paulo Escola de Engenharia de São Carlos Universidade Estadual Paulista Júlio de Mesquita Filho
Databáze: OpenAIRE