Reliability of Quantitative Assessment of Distal Radioulnar Joint Stability With Force-Monitor Ultrasonography
Autor: | Yuichi Yoshii, Wen-lin Tung, Tomoo Ishii, Hiroshi Yuine, Hideki Shiraishi |
---|---|
Rok vydání: | 2018 |
Předmět: |
Male
Wrist Joint Materials science Druj 0206 medical engineering Ulna 02 engineering and technology Wrist 03 medical and health sciences 0302 clinical medicine Forearm medicine Humans Orthopedics and Sports Medicine Displacement (orthopedic surgery) Reliability (statistics) Ultrasonography 030203 arthritis & rheumatology Orthodontics business.industry Ultrasound Reproducibility of Results 020601 biomedical engineering Radius medicine.anatomical_structure Transducer business |
Zdroj: | Journal of orthopaedic research : official publication of the Orthopaedic Research Society. 37(9) |
ISSN: | 1554-527X |
Popis: | The purpose of this study was to evaluate the reliability of ultrasound assessment of the displacement-force relationships for distal radioulnar joint (DRUJ) stability. Non-dominant wrists of 10 healthy male subjects were evaluated by force-monitor ultrasonography. This apparatus was developed to apply cyclic compression to the wrist with pre-determined transducer displacement conditions in the range of 0.1-3.0 mm. The subject's wrist was placed on the table with the forearm in the pronated position. The transducer was placed on the dorsal surface of the distal radius and ulna, perpendicular to the long axis of the forearm. The center of the ulnar head was at the DRUJ level. The distance between the dorsal surface of the distal radius and the ulnar head was measured at an initial and a pressed-down position. Changes in radioulnar displacement, force to the wrist and the displacement/force ratio were evaluated. The measurements were performed independently by two raters. The intra-class correlation coefficients (ICCs) for the radioulnar displacement were 0.76, 0.68, and 0.93, in the 1.0, 2.0, and 3.0 mm transducer displacement conditions, respectively. The ICCs for the force to the wrist were 0.18, 0.67, and 0.34, in different transducer displacement conditions, respectively. The ICCs for the displacement/force ratios were 0.68, 0.67, and 0.97, in different transducer displacement conditions, respectively. The highest ICC for the radioulnar displacement and the displacement/force ratio was observed in the 3.0 mm displacement condition. This assessment of displacement-force relationships may be useful to quantify DRUJ stability. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 37:2053-2060, 2019. |
Databáze: | OpenAIRE |
Externí odkaz: |