Application of MEKC and UPLC with Fluorescence Detection for Simultaneous Determination of Amlodipine Besylate and Bisoprolol Fumarate
Autor: | Fawzy A. El Yazbi, Tarek S. Belal, Rasha A. Shaalan, Hytham M. Ahmed, Sohila M. Elonsy |
---|---|
Rok vydání: | 2020 |
Předmět: |
Bisoprolol Fumarate
01 natural sciences High-performance liquid chromatography Micellar electrokinetic chromatography Analytical Chemistry chemistry.chemical_compound Chromatography detector medicine Environmental Chemistry Bisoprolol Amlodipine Acetonitrile Antihypertensive Agents Chromatography High Pressure Liquid Chromatography Micellar Electrokinetic Capillary Pharmacology Chromatography 010405 organic chemistry 010401 analytical chemistry Fluorescence 0104 chemical sciences chemistry Valsartan Agronomy and Crop Science Food Science medicine.drug |
Zdroj: | Journal of AOAC International. 104(2) |
ISSN: | 1944-7922 |
Popis: | Objective Two chromatographic methods were described for simultaneous determination of the antihypertensive drugs amlodipine besylate (AML) and bisoprolol fumarate (BIS). Methods Method I applies micellar electrokinetic capillary chromatography using a deactivated fused silica capillary (25 cm effective length × 50 μm internal diameter). The background electrolyte consisted of 0.01 M borate buffer (pH 9.2) containing 0.025 M sodium dodecyl sulphate and methanol in the ratio of 80:20 (v/v). Valsartan (VAL) was used as an internal standard. Diode array detector was set at 238, 224, and 210 nm for measuring AML, BIS, and VAL, respectively. Method II involves using ultra-performance liquid chromatography with fluorescence detection. Zorbax SB-C8 column (2.1 × 100 mm, 1.8 μm particle size) was used with isocratic elution of the mobile phase composed of 0.1% trifluoroacetic acid, acetonitrile, and methanol in the ratio of 55:35:10 (v/v) at a flow rate of 0.6 mL/min. Fluorescence detection was done using excitation wavelengths 230 and 370 nm and emission wavelengths 305 and 450 nm for BIS and AML, respectively. Validation parameters were carefully studied including linearity, ranges, precision, accuracy, robustness, detection, and quantification limits. Results Method I showed good linearity over the range 10–100 μg/mL for both dugs. Method II’s linear ranges were 0.001–0.1 and 0.02–1 µg/mL for BIS and AML, respectively. Conclusion The proposed methods were successfully validated and applied for assay of the studied drugs in their fixed-dose combination tablets. Highlights To the best of our knowledge, this study suggests the first electro-chromatographic and LC with fluorescence detection methods for simultaneous determination of amlodipine and bisoprolol. |
Databáze: | OpenAIRE |
Externí odkaz: |