ЭФФЕКТИВНОСТЬ ПРИМЕНЕНИЯ ПОЛУПРОВОДЯЩИХ ПОКРЫТИЙ ДЛЯ РЕГУЛИРОВАНИЯ ЭЛЕКТРИЧЕСКОГО ПОЛЯ В ВЫСОКОВОЛЬТНОЙ ИЗОЛЯЦИИ ЭЛЕКТРИЧЕСКИХ МАШИН
Autor: | G. V. Bezprozvannych, A. V. Roginskiy |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2019 |
Předmět: |
621.319
external partial discharges long-term electric and thermal aging frontal part of the rod electric field regulation of the electric field semiconductive coating surface resistivity distribution of electric potential stability of nonlinear properties long-term electric and thermal agin TK1-9971 лобовая часть стержня внешние частичные разряды электрическое поле регулирование электрического поля противокоронне полупроводящее покрытие удельное поверхностное сопротивление распределение электрического потенциала стабильность нелинейных свойств Electrical engineering. Electronics. Nuclear engineering |
Zdroj: | Electrical engineering & Electromechanics, Iss 6, Pp 44-49 (2019) Electrical Engineering & Electromechanics; № 6 (2019): Electrical Engineering & Electromechanics №6 2019; 44-49 Электротехника и Электромеханика; № 6 (2019); 44-49 Електротехніка і Електромеханіка; № 6 (2019): Електротехніка і Електромеханіка №6 2019; 44-49 |
ISSN: | 2309-3404 2074-272X |
Popis: | Introduction. Intensification of competition and the desire to reduce the cost of high-voltage electric machines due to a significant increase in the electrical and thermal loads of the electrical insulation system complicate the operation of anti-corona coatings on the insulation surface of the stator winding and increase the intensity of discharge processes, which significantly reduce the life of the insulation in case of failure of the coatings. Purpose. The analysis of the efficiency of alignment of the electric field along the insulation surface of the stator winding of high-voltage electric machines with semiconductor anti-corona coatings. Methodology. A method for calculating the electric potential distribution along the surface of the winding insulation during the use of semiconductive coatings providing alignment decrease the electric field and eliminating the appearance of moving discharges. The reliability of the calculations is confirmed by experimental studies of the potential distribution over the surface of the anti-corona semiconducting non-linear coating along the frontal part of the samples of the rod of the hydrogenerator for a linear voltage of 20 kV. Practical value. The proposed methodology for calculating the distribution of the electric field over the surface of the insulation and the anti-corona semiconductive coating can be applied to justify the length of the coating in the frontal part of high-voltage electrical machines depending on the electrophysical characteristics of the coating, electrical insulation, and thickness. The results of an experimental verification of the stability of the nonlinear properties of coatings during prolonged electrical and thermal aging of specially made coating samples are presented. Представлена методика расчета распределения электрического поля по поверхности изоляции и противокоронного полупроводящего покрытия в лобовой части стержня высоковольтной электрической машины. Получено в зависимости от удельного поверхностного сопротивления полупроводящего покрытия распределение электрического потенциала по поверхности противокоронного покрытия и изоляции. Обоснован диапазон значений удельного поверхностного сопротивления противокоронного покрытия для эффективного регулирования электрического поля. Достоверность расчетов подтверждена экспериментальными исследованиями распределения потенциала по поверхности противокоронного полупроводящего нелинейного покрытия вдоль лобовой части образцов стрежней гидрогенератора на линейное напряжение 20 кВ. Представлены результаты экспериментальной проверки стабильности нелинейных свойств покрытий в процессе длительного электрического и теплового старения специально изготовленных образцов покрытия. Эффективность регулирования электрического поля полупроводящими покрытиями подтверждена результатами испытаний образцов стрежней гидрогенератора СВ 1500/100-12 в исходном состоянии и после комплексного длительного воздействия электрического поля и температуры. |
Databáze: | OpenAIRE |
Externí odkaz: |