C-reactive protein and drain amylase: their utility in ruling out anastomotic leakage after minimally invasive Ivor-Lewis esophagectomy

Autor: Sanne K. Stuart, Toon J. L. Kuypers, Ingrid S. Martijnse, Joos Heisterkamp, Robert A. Matthijsen
Rok vydání: 2022
Předmět:
Zdroj: Scandinavian Journal of Gastroenterology. 58:448-452
ISSN: 1502-7708
0036-5521
DOI: 10.1080/00365521.2022.2141076
Popis: Anastomotic leakage (AL) is one of the most feared complications after esophagectomy for esophageal cancer. We investigated the role of serum C-reactive protein (CRP) and drain amylase levels in the early detection of AL. This is a retrospective study of 193 patients who underwent a minimally invasive Ivor-Lewis procedure between January 2017 and October 2021. Mean CRP and median drain amylase levels between patients with and without AL were compared during the first five postoperative days (POD). ROC curves on POD 3, 4 and 5 were plotted to calculate cut-off values for CRP. In 30 of the 193 patients (16%), AL was diagnosed with a median time to diagnosis of 9 days. Mean CRP was significantly higher in patients with AL on POD 3, 4 and 5. Cut-off values of 59, 110 and 106 mg/L had a high sensitivity of 93%, 90% and 90% on POD 3, 4 and 5. No difference in median drain amylase levels was observed. CRP levels with a cut-off point of 110 mg/L on POD 4 do not improve earlier detection of AL, but have a high sensitivity for excluding AL. The value of drain amylase in the first 5 days after surgery is limited.