Stability of Hemoglobin Constant Spring Identified by Capillary Electrophoresis

Autor: Jidapa, Jaitheang, Amornchai, Suksusut, Rung, Settapiboon, Supaporn, Amornsiriwat, Pranee, Sutcharitchan, Noppacharn, Uaprasert, Ponlapat, Rojnuckarin
Rok vydání: 2022
Předmět:
Zdroj: Laboratory Medicine. 54:e91-e94
ISSN: 1943-7730
0007-5027
Popis: Objective Hemoglobin Constant Spring (HbCS) is often missed by routine hemoglobin analysis. The aim of this research was to study HbCS stability as identified by capillary electrophoresis (CE) to determine the specimen storage time limit. Methods The EDTA blood of 29 HbCS samples were kept at 4°C and analyzed every workday until CE could not detect HbCS or until 7 weeks after blood collection. The genotypes were confirmed by multiplex polymerase chain reaction. Results The median subject age was 27 years and 10 subjects were male. The HbCS levels were stable during the first 7 days but became undetectable in 5 cases (17.2%) after 1 week. All of them were heterozygous HbCS. Longer detection times were correlated with the higher baseline HbCS levels, with a correlation coefficient of 0.582 (P ≤ 0.001) Conclusion Routine hemoglobin typing and quantitation should be performed within 1 week after blood collection to detect low HbCS levels, especially in heterozygous HbCS.
Databáze: OpenAIRE