Validation of a novel stand-alone software tool for image guided cardiac catheter therapy

Autor: E.R. Nieuwenhuis, Frebus J. van Slochteren, René van Es, Adriaan O. Kraaijeveld, Leon de Jong, Hans T. van den Broek, Steven A. J. Chamuleau, Pieter A. Doevendans, Mira van der Naald
Přispěvatelé: Magnetic Detection and Imaging
Jazyk: angličtina
Rok vydání: 2019
Předmět:
Cardiac Catheterization
Time Factors
Sus scrofa
Myocardial Infarction
Infarction
Contrast Media
030204 cardiovascular system & hematology
Pre-clinical research
Arrhythmias
Magnetic Resonance Imaging
Interventional

Radiography
Interventional

Myocardial Infarction/diagnostic imaging
Coronary Angiography
Multimodal Imaging
030218 nuclear medicine & medical imaging
Imaging
0302 clinical medicine
Interventional/methods
Occlusion
Three-Dimensional/methods
Clinical endpoint
Computer-Assisted/methods
Medicine
Fluoroscopy
Contrast Media/administration & dosage
Cardiac imaging
Image guided therapy
medicine.diagnostic_test
Magnetic Resonance Imaging
Catheter
Imaging
Three-Dimensional/methods

Radiology Nuclear Medicine and imaging
Myocardial viability imaging
Female
Electrophysiologic Techniques
Electrophysiologic Techniques
Cardiac

Cardiology and Cardiovascular Medicine
Cardiac
Cardiac/etiology
MRI
Image-Guided Therapy
Magnetic Resonance Imaging
Interventional/methods

Arrhythmias
Cardiac/etiology

Injections
03 medical and health sciences
Imaging
Three-Dimensional

Radiography
Interventional/methods

Predictive Value of Tests
Image Interpretation
Computer-Assisted

Journal Article
Animals
Radiology
Nuclear Medicine and imaging

Validation Studies
Innovation
Image Interpretation
Original Paper
business.industry
Animal
Image Interpretation
Computer-Assisted/methods

Reproducibility of Results
Arrhythmias
Cardiac

Gold standard (test)
medicine.disease
Radiography
Disease Models
Animal

Hybrid imaging
Disease Models
Cardiac Catheterization/adverse effects
business
Nuclear medicine
Software
Zdroj: The International Journal of Cardiovascular Imaging, 35(2), 225. Springer Netherlands
The International Journal of Cardiovascular Imaging
International journal of cardiovascular imaging, 35(2), 225-235. Springer
ISSN: 1569-5794
Popis: Comparison of the targeting accuracy of a new software method for MRI-fluoroscopy guided endomyocardial interventions with a clinically available 3D endocardial electromechanical mapping system. The new CARTBox2 software enables therapy target selection based on infarction transmurality and local myocardial wall thickness deduced from preoperative MRI scans. The selected targets are stored in standard DICOM datasets. Fusion of these datasets with live fluoroscopy enables real-time visualization of MRI defined targets during fluoroscopy guided interventions without the need for external hardware. In ten pigs (60–75 kg), late gadolinium enhanced (LGE) MRI scans were performed 4 weeks after a 90-min LAD occlusion. Subsequently, 10–16 targeted fluorescent biomaterial injections were delivered in the infarct border zone (IBZ) using either the NOGA 3D-mapping system or CARTBox2. The primary endpoint was the distance of the injections to the IBZ on histology. Secondary endpoints were total procedure time, fluoroscopy time and dose, and the number of ventricular arrhythmias. The average distance of the injections to the IBZ was similar for CARTBox2 (0.5 ± 3.2 mm) and NOGA (− 0.7 ± 2.2 mm; p = 0.52). Injection procedures with CARTBox2 and NOGA required 69 ± 12 and 60 ± 17 min, respectively (p = 0.36). The required endocardial mapping procedure with NOGA prior to injections, leads to a significantly longer total procedure time (p
Databáze: OpenAIRE