Central vein rupture during percutaneous transluminal angioplasty for central vein stenosis or occlusion in haemodialysis patients
Autor: | Seung Boo Yang, W. Lee, Jae Man Lee, Beum Jin Kim, Yong J. Kim, Dong E. Goo, Young J. Kim |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2017 |
Předmět: |
lcsh:Medical physics. Medical radiology. Nuclear medicine
medicine.medical_specialty Percutaneous Balloon tamponade lcsh:R895-920 medicine.medical_treatment 030204 cardiovascular system & hematology 03 medical and health sciences 0302 clinical medicine 030225 pediatrics Occlusion Medicine Radiology Nuclear Medicine and imaging Vein Radiological and Ultrasound Technology business.industry Stent medicine.disease Thrombosis Surgery PTA central vein Stenosis medicine.anatomical_structure surgical procedures operative Hemodialysis cardiovascular system Radiology business |
Zdroj: | SA Journal of Radiology, Volume: 21, Issue: 1, Pages: 1-5, Published: 2017 South African Journal of Radiology, Vol 21, Iss 1, Pp e1-e5 (2017) |
Popis: | Background: Endovascular treatments such as percutaneous transluminal angioplasty (PTA) and stent placements are becoming the standard method in managing haemodialysis access failure. Venous rupture is the most common complication during endovascular procedures. Complications during endovascular treatments of central venous stenosis or occlusion have been rarely reported. Objectives: To investigate the incidence and management of central vein rupture while performing PTA for central vein stenosis or occlusion in haemodialysis patients. Method: Between 1998 and 2013, PTA was performed using various techniques in haemodialysis patients for central vein stenoses ( n = 2437) and occlusions ( n = 666). When the guide wire passed through the stenosis or the occlusion, PTA was performed regardless of the presence of a venous rupture. The incidence of central vein rupture was analysed using the chi-square test according to the gender, location, right versus left, presence of thrombosis and stenosis versus occlusion. Percutaneous management of central vein rupture was also evaluated. Results: Central vein rupture occurred in 12 cases (0.39%). All ruptures occurred in the cases with occlusion. Only stenosis versus occlusion reflected a significant correlation ( p < 0.001) with central vein rupture. Central vein ruptures were managed by low-pressure balloon tamponade ( n = 2), stent/stent-graft ( n = 5) and balloon-mediated haemostasis blocking venous inflow followed by the observation ( n = 5). Conclusion: Central vein rupture is a rarely occurring complication while performing PTA for central vein stenosis and occlusion, and the majority can be successfully managed by percutaneous techniques. |
Databáze: | OpenAIRE |
Externí odkaz: |