Percutaneous measurement of portal blood flow in the piglet by continuous thermodilution
Autor: | H. Michel, D. Mirouze, G. Marchal, J. Thuile, P. Bories, P. Bauret, J. L. Rique |
---|---|
Rok vydání: | 2008 |
Předmět: |
Vena porta
Percutaneous Portography Hepatology Swine Tissue Extracts business.industry Electromagnetic flowmetry animal diseases Coefficient of variation Thermodilution Portal vein Blood flow Portal System medicine.anatomical_structure Pituitary Gland Anesthesia Portal blood Animals Medicine Rheology business Blood Flow Velocity Biomedical engineering Blood vessel |
Zdroj: | Liver. 5:221-225 |
ISSN: | 0106-9543 |
DOI: | 10.1111/j.1600-0676.1985.tb00241.x |
Popis: | — The continuous thermodilution method was applied to the percutaneous measurement of portal blood flow in the piglet by inserting a thermodilution probe into the portal vein via the transhepatic transvenous route. The method was compared to electromagnetic flowmetry in three piglets; the two methods yielded statistically identical results. The coefficient of variation of the continuous thermodilution measurements was 4%. The method allows portal blood flow measurements that are instantaneous, reliable, reproducible, and repetitive. It was applied to a study of rapid flow variations in piglets receiving an infusion of posterior pituitary extract. |
Databáze: | OpenAIRE |
Externí odkaz: |