The Comparative Analysis of Automatic Control Systems for the Heat Supply of Residential Buildings in Monotonous Transient Processes and in Processes Recommended by Regulator Manufacturers
Autor: | A. A. Baldenkov, Vladimir L. Kodkin, A. S. Anikin |
---|---|
Rok vydání: | 2018 |
Předmět: |
Engineering
Automatic control business.industry Heat supply Regulator General Medicine Coolant flow Automotive engineering optimization of heating system УДК 658.264 coolant flow энергоэффективность зданий process optimization coolant temperature control поток жидкости Russian federation Transient (oscillation) контроль температуры жидкости energy efficiency of buildings оптимизация системы отопления business 662.92 [УДК 620.9] оптимизация процессов |
Zdroj: | Bulletin of the South Ural State University. Ser. Computer Technologies, Automatic Control & Radioelectronics. 18:156-163 |
ISSN: | 2409-6571 1991-976X |
DOI: | 10.14529/ctcr180216 |
Popis: | Кодкин Владимир Львович, д-р техн. наук, профессор кафедры автоматизированного электропривода, Южно-Уральский государственный университет, г. Челябинск; kodkina2@mail.ru. Аникин Александр Сергеевич, доцент кафедры теоретических основ электротехники, Южно- Уральский государственный университет, г. Челябинск; anikinas@susu.ru. Балденков Александр Александрович, аспирант кафедры автоматизированного электропривода, Южно-Уральский государственный университет, г. Челябинск; baloo@mail.ru. V.L. Kodkin, kodkina2@mail.ru, A.S. Anikin, anikinas@susu.ru, A.A. Baldenkov, baloo@mail.ru South Ural State University, Chelyabinsk, Russian Federation Results of studies of the automatic regulation system of a residential complex along the street of Academician Sakharov in the city of Chelyabinsk are given in article. The analysis of actual indicators of volumes of consumed gas within several months 2015–2017 is carried out depending on average daily temperature of external air. It is shown that the adjustment of the controller by the factory method does not ensure the effective functioning of the heat supply system, especially at ambient temperatures close to 0 °C. The comparison was carried out in two ways: by the method of equivalent trends and by the average temperature and consumption of gas per month. The conducted analysis convincingly proves that the control system with monotonic processes is not only more effective from the point of view of the operation of the equipment, but also from the point of view of energy efficiency. Приведены результаты исследований системы автоматического регулирования жилого комплекса по ул. Академика Сахарова в городе Челябинске. Анализ фактических показателей объемов потребляемого газа в течение нескольких месяцев 2015–2017 гг. осуществлялся в зависимости от среднесуточной температуры наружного воздуха. Показано, что регулировка контроллера по рекомендации завода изготовителя не обеспечивает эффективного функционирования системы теплоснабжения, особенно при температуре окружающей среды, близкой к 0 °C. Сравнение проводилось двумя способами: методом эквивалентных тенденций и средней температурой и потреблением газа в месяц. Проведенный анализ убедительно доказывает, что система управления с монотонными процессами не только более эффективна с точки зрения работы оборудования, но и с точки зрения энергоэффективности. |
Databáze: | OpenAIRE |
Externí odkaz: |